OBJECTIVE Needle-implantable sensors have shown to provide reliable continuous glucose monitoring for diabetes management. In order to reduce tissue injury during sensor implantation, there is a constant need for device size reduction, which imposes challenges in terms of sensitivity and reliability, as part of decreasing signal-to-noise and increasing layer complexity. Herein, we report sensitivity enhancement via electrochemical surface rebuilding of the working electrode (WE), which creates a three-dimensional nanoporous configuration with increased surface area. METHODS The gold WE was electrochemically rebuilt to render its surface nanoporous followed by decoration with platinum nanoparticles. The efficacy of such process was studied using sensor sensitivity against hydrogen peroxide (H2O2). For glucose detection, the WE was further coated with five layers, namely, (1) polyphenol, (2) glucose oxidase, (3) polyurethane, (4) catalase, and (5) dexamethasone-releasing poly(vinyl alcohol)/poly(lactic-co-glycolic acid) composite. The amperometric response of the glucose sensor was noted in vitro and in vivo. RESULTS Scanning electron microscopy revealed that electrochemical rebuilding of the WE produced a nanoporous morphology that resulted in a 20-fold enhancement in H2O2 sensitivity, while retaining >98% selectivity. This afforded a 4-5-fold increase in overall glucose response of the glucose sensor when compared with a control sensor with no surface rebuilding and fittable only within an 18 G needle. The sensor was able to reproducibly track in vivo glycemic events, despite the large background currents typically encountered during animal testing. CONCLUSION Enhanced sensor performance in terms of sensitivity and large signal-to-noise ratio has been attained via electrochemical rebuilding of the WE. This approach also bypasses the need for conventional and nanostructured mediators currently employed to enhance sensor performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zwitterionic poly(carboxybetaine) hydrogels for glucose biosensors in complex media.

Zwitterionic hydrogels based on poly(carboxybetaine) methacrylate (polyCBMA) were developed to protect implantable electrochemical glucose biosensors from biofouling in complex media. To enhance the linearity and sensitivity of the sensing profile, both physical and chemical adsorption methods were developed. Results show that glucose sensors coated with polyCBMA hydrogels via the chemical meth...

متن کامل

The obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4

The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...

متن کامل

The obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4

The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...

متن کامل

Application of Graphene and Graphene Oxide for modification of electrochemical sensors and biosensors: A review

This paper gives a comprehensive review about the most recent progress in graphene and graphene oxide based electrochemical sensors and biosensors.  Graphene, emerging as a true 2-dimensional material, has received increasing attention due to its unique physicochemical properties (high surface area, excellent conductivity, high mechanical strength, and ease of functionalization and mass product...

متن کامل

Application of Graphene and Graphene Oxide for modification of electrochemical sensors and biosensors: A review

This paper gives a comprehensive review about the most recent progress in graphene and graphene oxide based electrochemical sensors and biosensors.  Graphene, emerging as a true 2-dimensional material, has received increasing attention due to its unique physicochemical properties (high surface area, excellent conductivity, high mechanical strength, and ease of functionalization and mass product...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 2013