Specific and Simple HPLC Assay of Ecofriendly Meloxicam in Pharmaceutical Formulations
نویسنده
چکیده
A simple, precise, specific ,robust and rapid HPLC assay for the of measurement meloxicam in pharmaceutical formulations was developed and validated at Department of Pharmacy and Central Quality Assurance Laboratory, LCWU, Lahore. The solution of meloxicam standard was prepared in HPLC grade acetonitrile (5 μg.mL) and ultra sonicated for 15 minutes. One mL sample mixed well with one mL of HPLC grade water and filtered through 0.22 μm filter. Ten micro-litter sample was injected into HPLC system through an injector valve with a ten micro-litter sample loop. The mobile phase comprising of phosphate buffer(0.2 Normal) and acetonitrile (38:62, v/v) was pumped into Water 1525 Binary HPLC Pump 1525 at the rate 0.5mL/min Separation was achieved by using a reversed phase C18 column (Phenomenex, particle size 5 μm;4.6 mm ×150 mm) at retention time of 7.4 minutes. Oven temperature was set at 25 °C. The meloxicam was distinctly and specifically detected at 352nm by using Water 2487 dual absorbance detectors. The method was validated prior to the analysis of samples. The limit of detection and limit of quantification were .0.06 and 6 micrograms respectively. The sample from commercial pharmaceutical formulation were prepared in HPLC grade methanol in concentration of 5 μg.mL. The developed and validated method was successfully applied for assay of meloxicam in these formulations including injections, tablets and suspension.
منابع مشابه
Indirect flow-injection spectrophotometric determination of meloxicam, tenoxicam and piroxicam in pharmaceutical formulations.
A simple and sensitive indirect spectrophotometric method for the assay of meloxicam (MX), tenoxicam (TX) and piroxicam (PX) in pure and in pharmaceutical formulations by flow injection analysis (FIA) has been proposed. The method is based on the oxidation of these drugs by a known excess of N-bromosuccinimide (NBS) in an acidic medium, followed by a reaction of excess oxidant with chloranilic ...
متن کاملOptimization and validation of RP-HPLC method for the estimation of meloxicam and paracetamol with its genotoxic impurity (p-amino phenol) in bulk and pharmaceutical drug product using PDA detector
A simple, accurate, precise, reproducible RP-HPLC method has been developed for simultaneous estimation of meloxicam and paracetamol with its genotoxic impurity (p-amino phenol) in bulk and combined dosage form (tablet). The method was validated in compliance with ICH guidelines[1-2]. The LC separation was achieved on Lichrospher RP-18e (250X4.6mm), 5μm column at 285 nm in isocratic mode using ...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کامل