Optimization of inversion time for postmortem short-tau inversion recovery (STIR) MR imaging.

نویسندگان

  • Tomoya Kobayashi
  • Masahiko Monma
  • Takeshi Baba
  • Yoshiyuki Ishimori
  • Seiji Shiotani
  • Hajime Saitou
  • Kazunori Kaga
  • Katsumi Miyamoto
  • Hideyuki Hayakawa
  • Kazuhiro Homma
چکیده

PURPOSE Signal intensity and image contrast differ between postmortem magnetic resonance (PMMR) images and images acquired from the living body. We sought to achieve sufficient fat suppression with short-tau inversion recovery (STIR) PMMR imaging by optimizing inversion time (TI). MATERIAL AND METHODS We subjected 37 deceased adult patients to PMMR imaging at 1.5 tesla 8 to 60 hours after confirmation of death and measured T1 values of areas of subcutaneous fat with relaxation time maps. Rectal temperature (RT) measured immediately after PMMR ranged from 6 to 31°C. We used Pearson's correlation coefficient to analyze the relationship between T1 and relaxation time (RT). We compared STIR images from 4 cadavers acquired with a TI commonly used in the living body and another TI calculated from the linear regression of T1 and RT. RESULTS T1 values of subcutaneous fat ranged from 89.4 to 182.2 ms. There was a strong, positive, and significant correlation between T1 and RT (r = 0.91, P < 0.0001). The regression expression for the relationship was T1 = 2.6*RT + 90 at a field strength of 1.5T. The subcutaneous fat signal was suppressed more effectively with the optimized TI. CONCLUSION The T1 value of subcutaneous fat in PMMR correlates linearly with body temperature. Using this correlation to determine TI, fat suppression with PMMR STIR imaging can be easily improved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The STIR sequence in MR imaging.

A recent paper on MR imaging of infectious spondylitis [1) elaborated on and substantiated a previous report [2) of STIR in the evaluation of spinal infection. However, it also contained an important error in pulse sequence nomenclature: STIR was described as "short T1 inversion recovery. " The STIR sequence was described and named by Drs. Bydder, Young, and Steiner [3 , 4) as "short Tl inversi...

متن کامل

Turbo short tau inversion recovery imaging for metastatic node screening in patients with head and neck cancer.

BACKGROUND AND PURPOSE A rapid and sensitive MR imaging technique would be beneficial for screening of metastatic nodes in the neck. We preliminarily evaluated the coronal MR imaging with a turbo short tau inversion recovery (STIR) sequence for that purpose. METHODS The coronal turbo STIR imaging (repetition time [TR]/echo time [TE]/inversion time [TI] = 3850 ms/20 or 80 ms/180 ms) and axial ...

متن کامل

STIR MR imaging of the orbit.

Fifteen patients with CT-documented orbital lesions were evaluated with MR imaging at 1.5 T with both conventional spin-echo (SE) and short inversion time inversion recovery (STIR) sequences. Fat signal was reliably nulled at inversion times of approximately 120-200 msec in all cases, thereby allowing clear detection of all retrobulbar lesions and normal structures on STIR images as markedly hy...

متن کامل

MR evaluation of vertebral metastases: T1-weighted, short-inversion-time inversion recovery, fast spin-echo, and inversion-recovery fast spin-echo sequences.

PURPOSE To compare the detectability of vertebral metastatic disease on T1-weighted, short-inversion-time inversion recovery (STIR), fast spin-echo (FSE), fat-saturated FSE, and inversion recovery FSE (IRFSE) MR sequences using percent contrast and contrast-to-noise ratios. METHODS Patients with proved metastatic disease underwent imaging on a 1.5-T MR system with sagittal T1-weighted (800/20...

متن کامل

Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system.

Fat suppression is an important technique in musculoskeletal imaging to improve the visibility of bone-marrow lesions; evaluate fat in soft-tissue masses; optimize the contrast-to-noise ratio in magnetic resonance (MR) arthrography; better define lesions after administration of contrast material; and avoid chemical shift artifacts, primarily at 3-T MR imaging. High-field-strength (eg, 3-T) MR i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 2014