Measuring statistical agreement between four point of care (POC) lactate meters and a laboratory blood analyzer in cats.

نویسندگان

  • Mark J Acierno
  • Meghan E Johnson
  • Lee Ann Eddleman
  • Mark A Mitchell
چکیده

The use of blood lactate concentrations as a prognostic indicator and therapeutic gauge in feline medicine has been hindered by the inability to obtain values in a timely manner with minimal quantities of blood. Recently, hand-held point-of-care (POC) lactate meters have become commercially available. The objective of this prospective study was to determine if lactate values produced by three commercially available and one medical grade POC meter were in agreement with a laboratory blood analyzer. Blood samples from 47 cats were collected on presentation to an emergency service and processed on four POC meters and a Stat Profile Critical Care Xpress blood analyzer. The results were analyzed using the Bland-Altman method. The blood lactate values produced by the hospital grade POC meter and one of the commercially POC meters were in good agreement with the Critical Care Xpress blood analyzer. Other commercially available POC meters produced acceptable agreement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of four point-of-care meters for rapid determination of blood lactate concentrations in dogs.

OBJECTIVE To determine whether blood lactate values determined in dogs with 4 commercially available point-of-care meters were in agreement with values determined with a critical care laboratory blood analyzer. DESIGN Prospective study. ANIMALS 50 dogs evaluated for emergency treatment. PROCEDURES Blood samples were collected at initial evaluation and processed on 4 point-of-care meters a...

متن کامل

Accuracy of Handheld Point-of-Care Fingertip Lactate Measurement in the Emergency Department

INTRODUCTION Early recognition of elevated lactate levels in sepsis may hasten the detection of those patients eligible for aggressive resuscitation. Point-of-care (POC) testing is now increasingly available for use in the emergency department (ED). We examined the accuracy and time-saving effect of a handheld POC device for the measurement of fingertip and whole blood lactate as compared with ...

متن کامل

Intraoperative accuracy of a point-of-care glucose meter compared with simultaneous central laboratory measurements.

BACKGROUND Concerns have been raised about the use of point-of-care (POC) glucose meters in the hospital setting. Accuracy has been questioned especially in critically ill patients. Although commonly used in intensive care units and operating rooms, POC meters were not approved by the Food and Drug Administration for such use. Data on POC glucose meter performance during anesthesia are lacking....

متن کامل

Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

OBJECTIVE To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). ANIMALS 20 healthy adult Hispaniolan Amazon parrots. PROCEDURES A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) fro...

متن کامل

Validating a point of care lactate meter in adult patients with sepsis presenting to the emergency department of a tertiary care hospital of a low- to middle-income country.

BACKGROUND Timely identification of high blood lactate levels in septic patients may allow faster detection of those patients requiring immediate resuscitation. Point-of-care (POC) testing is being increasingly utilized in the emergency department (ED). We examined the accuracy and time-saving effect of a handheld POC lactate device for the measurement of fingertip and whole blood lactate as co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of feline medicine and surgery

دوره 10 2  شماره 

صفحات  -

تاریخ انتشار 2008