Comparative study of temperature measurements in ex vivo swine muscle and a tissue-mimicking material during high intensity focused ultrasound exposures.

نویسندگان

  • S Maruvada
  • Y Liu
  • W F Pritchard
  • B A Herman
  • G R Harris
چکیده

Tissue-mimicking materials (TMMs) can provide a convenient, stable, and reproducible means for testing high intensity focused ultrasound (HIFU) devices. When TMMs containing thermal sensors are used to measure ultrasound-induced temperature rise, it is important that measurement results reasonably represent those that occur in biological tissue. Therefore the aim of this paper is to compare the thermal behavior of the TMM under HIFU exposure to that of ex vivo tissue. This was accomplished using both a previously developed TMM and fresh ex vivo swine muscle that were instrumented with bare 50 µm thin wire thermocouples. HIFU at 825 kHz was focused at the thermocouple junction. 30 s exposures of increasing peak negative pressure (1 to 5 MPa) were applied and the temperature profile during and after sonication was recorded. B-mode imaging was used to monitor bubble activity during sonication. If bubble formation was noted during the sonication, the sonication was repeated at the same pressure levels two more times at 20 min intervals. Temperature traces obtained at various pressure levels demonstrated similar types of heating profiles in both the tissue and TMM, the exact nature of which depended on whether bubbles formed during the HIFU exposure. The onset of bubble activity occurred at lower ultrasonic pressures in the TMM, but the basic temperature rise features due to HIFU exposure were essentially the same for both materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Safety limitations of MR‐HIFU treatment near interfaces: a phantom validation

Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a noninvasive image-guided technique used to thermally ablate solid tumors. During treatment, ultrasound reflections from distal media interfaces can shift prescribed treatment locations. The purpose of this study was to investigate the effect of normal incidence reflections from air, acrylic (modeling bone), and rubber on...

متن کامل

Boiling histotripsy lesion characterization on a clinical magnetic resonance imaging-guided high intensity focused ultrasound system

PURPOSE High intensity focused ultrasound (HIFU) is a non-invasive therapeutic technique that can thermally ablate tumors. Boiling histotripsy (BH) is a HIFU approach that can emulsify tissue in a few milliseconds. Lesion volume and temperature effects for different BH sonication parameters are currently not well characterized. In this work, lesion volume, temperature distribution, and area of ...

متن کامل

Effect of lung flooding and high-intensity focused ultrasound on lung tumours: an experimental study in an ex vivo human cancer model and simulated in vivo tumours in pigs

BACKGROUND High-intensity focused ultrasound is a valuable tool for minimally invasive tumour ablation. However, due to the air content in ventilated lungs, lung tumours have never been treated with high-intensity focused ultrasound. Lung flooding enables efficient lung sonography and tumour imaging in ex vivo human and in vivo porcine lung cancer models. The current study evaluates the effecti...

متن کامل

T2-based temperature monitoring in bone marrow for MR-guided focused ultrasound

BACKGROUND Current clinical protocols for MR-guided focused ultrasound (MRgFUS) treatment of osseous lesions, including painful bone metastases and osteoid osteomas, rely on measurement of the temperature change in adjacent muscle to estimate the temperature of the bone. The goal of this study was to determine if T2-based thermometry could be used to monitor the temperature change in bone marro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 57 1  شماره 

صفحات  -

تاریخ انتشار 2012