Effectiveness of charged noncovalent polymer coatings against protein adsorption to silica surfaces studied by evanescent-wave cavity ring-down spectroscopy and capillary electrophoresis.

نویسندگان

  • Rob Haselberg
  • Lineke van der Sneppen
  • Freek Ariese
  • Wim Ubachs
  • Cees Gooijer
  • Gerhardus J de Jong
  • Govert W Somsen
چکیده

Protein adsorption to silica surfaces is a notorious problem in analytical separations. Evanescent-wave cavity ring-down spectroscopy (EW-CRDS) and capillary electrophoresis (CE) were employed to investigate the capability of positively charged polymer coatings to minimize the adsorption of basic proteins. Adsorption of cytochrome c (cyt c) to silica coated with a single layer of polybrene (PB), or a triple layer of PB, dextran sulfate (DS), and PB, was studied and compared to bare silica. Direct analysis of silica surfaces by EW-CRDS revealed that both coatings effectively reduce irreversible protein adsorption. Significant adsorption was observed only for protein concentrations above 400 microM, whereas the PB-DS-PB coating was shown to be most effective and stable. CE analyses of cyt c were performed with and without the respective coatings applied to the fused-silica capillary wall. Monitoring of the electroosmotic flow and protein peak areas indicated a strong reduction of irreversible protein adsorption by the positively charged coatings. Determination of the electrophoretic mobility and peak width of cyt c revealed reversible protein adsorption to the PB coating. It is concluded that the combination of results from EW-CRDS and CE provides highly useful information on the adsorptive characteristics of bare and coated silica surfaces toward basic proteins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of two types of silanol groups on fused-silica surfaces using evanescent-wave cavity ring-down spectroscopy.

Evanescent-wave cavity ring-down spectroscopy has been applied to a planar fused-silica surface covered with crystal violet (CV+) cations to characterize the silanol groups indirectly. A radiation-polarization dependence of the adsorption isotherm of CV+ at the CH3CN/silica interface is measured and fit to a two-site Langmuir equation to determine the relative populations of two different types...

متن کامل

Noncovalent polycationic coatings for capillaries in capillary electrophoresis of proteins.

The adsorption of proteins with net positive charges (pI > pH) on the walls of fused-silica capillaries is a common problem in the analysis of proteins by capillary electrophoresis. This paper explores the use of polycationic polymers as noncovalent coatings to limit this problem. The behavior of three sets of proteins was compared using uncoated and coated capillaries: (i) a protein charge lad...

متن کامل

Evanescent-wave cavity ring-down investigation of polymer/solvent interactions.

Evanescent-wave cavity ring-down spectroscopy (EW-CRDS) is used to measure interfacial phenomena when methanol or water is placed in contact with a film of poly(dimethylsiloxane) (PDMS), which is attached to the face of a fused-silica prism that constitutes part of a ring cavity. In the first few minutes after contact, the uptake of methanol is slower than that of water, but after this initial ...

متن کامل

Molecular adsorption at silica/CH3CN interface probed by using evanescent wave cavity ring-down absorption spectroscopy: determination of thermodynamic properties.

Evanescent wave cavity ring-down absorption spectroscopy is applied to measure the thermodynamic properties of the surface adsorption for neutral trans-4-[4-(dibutylamino)styryl]-1-(3-sulfopropyl) pyridinium (DP) and charged trans-4-[4-(dibutylamino)styryl]-1-methylpyridinium iodide (DMP+ I-) at the silica/CH3CN interface, where the interfacial density is determined by measurement of absorbance...

متن کامل

Molecular orientation study of methylene blue at an air/fused-silica interface using evanescent-wave cavity ring-down spectroscopy.

Using evanescent-wave cavity ring-down spectroscopy (EW-CRDS), we monitored the change in the absorbance of a thin film of methylene blue (MB) at an air/fused-silica interface while varying the polarization of the incident light (600 nm). We derived the average orientation angle of the planar MB molecules with respect to the surface normal and observed that the average orientation angle decreas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 81 24  شماره 

صفحات  -

تاریخ انتشار 2009