Random calibration for accelerating MR-ARFI guided ultrasonic focusing in transcranial therapy.

نویسندگان

  • Na Liu
  • Antoine Liutkus
  • Jean-François Aubry
  • Laurent Marsac
  • Mickael Tanter
  • Laurent Daudet
چکیده

Transcranial focused ultrasound is a promising therapeutic modality. It consists of placing transducers around the skull and emitting shaped ultrasound waves that propagate through the skull and then concentrate on one particular location within the brain. However, the skull bone is known to distort the ultrasound beam. In order to compensate for such distortions, a number of techniques have been proposed recently, for instance using Magnetic Resonance Imaging feedback. In order to fully determine the focusing distortion due to the skull, such methods usually require as many calibration signals as transducers, resulting in a lengthy calibration process. In this paper, we investigate how the number of calibration sequences can be significantly reduced, based on random measurements and optimization techniques. Experimental data with six human skulls demonstrate that the number of measurements can be up to three times lower than with the standard methods, while restoring 90% of the focusing efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR-guided adaptive focusing of therapeutic ultrasound beams in the human head.

PURPOSE This study aims to demonstrate, using human cadavers the feasibility of energy-based adaptive focusing of ultrasonic waves using magnetic resonance acoustic radiation force imaging (MR-ARFI) in the framework of non-invasive transcranial high intensity focused ultrasound (HIFU) therapy. METHODS Energy-based adaptive focusing techniques were recently proposed in order to achieve aberrat...

متن کامل

Rapid MR-ARFI method for focal spot localization during focused ultrasound therapy.

MR-guided focused ultrasound (FUS) is a noninvasive therapy for treating various pathologies. MR-based acoustic radiation force imaging (MR-ARFI) measures tissue displacement in the focal spot due to acoustic radiation force. MR-ARFI also provides feedback for adaptive focusing algorithms that could correct for phase aberrations caused by the skull during brain treatments. This work developed a...

متن کامل

Optimal Ultrasonic Focusing through Strongly Aberrating Media using Radiation Force Magnetic Resonance Guidance

When focusing ultrasound through strongly aberrating layers such as bones, adaptive focusing techniques need to be used. They aim at recovering the delays to be applied to each emission channel of the ultrasonic (US) therapeutic array in order to compensate the phase shifts induced by the aberrator. We recently proposed a new energy-based technique requiring the sole knowledge of the acoustic i...

متن کامل

Application of Zernike polynomials towards accelerated adaptive focusing of transcranial high intensity focused ultrasound.

PURPOSE To study the phase aberrations produced by human skulls during transcranial magnetic resonance imaging guided focused ultrasound surgery (MRgFUS), to demonstrate the potential of Zernike polynomials (ZPs) to accelerate the adaptive focusing process, and to investigate the benefits of using phase corrections obtained in previous studies to provide the initial guess for correction of a ne...

متن کامل

Focal Spot Visualization in MRgFUS of the Breast: MR-ARFI vs. T1-weighted FSE

Introduction MRI guided focused ultrasound (MRgFUS) as a non-invasive breast cancer treatment has recently shown promising results in clinical trials [1,2,3]. Currently, during the planning stage of MRgFUS in the breast, a low temperature test spot is created to verify the actual location of the focal spot in relation to the planned position [1,2]. The test spots are visualized using proton res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 60 3  شماره 

صفحات  -

تاریخ انتشار 2015