Ahmed glaucoma valve and single-plate Molteno implants in treatment of refractory glaucoma: a comparative study.
نویسندگان
چکیده
PURPOSE To report 2-year follow-up data after Ahmed valve implantation (New World Medical, Inc) and Molteno single-plate implantation surgical treatment of refractory glaucoma. DESIGN Prospective, randomized, comparative study. METHODS Patients with refractory glaucoma, defined as uncontrolled intraocular pressure (IOP) of more than 21 mm Hg despite maximal antiglaucoma medication, previously failed nonseton surgical treatment, or a combination thereof were included. Ninety-two patients were allocated randomly to each of the study groups and underwent implantation of either the Ahmed valve implant (model FP7; 184 mm(2) surface area) or Molteno single-plate implant (134 mm(2) surface area) and were followed up for 24 months. Main outcome measures were IOP and surgical success rate. Other outcome measures were changes in visual acuity, number of ant-glaucoma medications, mean deviation of visual field, and rate of intraoperative and postoperative complications. RESULTS Those who successfully completed the trial (28 in the Molteno group and 29 in the Ahmed group) achieved significantly less IOP and fewer glaucoma medications, but worse visual acuity 24 months after surgery. The Molteno group, compared with the Ahmed group, achieved significantly lower IOPs after the early postoperative period until the end of the study. Both groups reasonably maintained visual field during the follow-up. The rate of surgical failure was comparable in both groups. Median survival time was 24 months for both groups. There were no devastating intraoperative or postoperative complications in either group. CONCLUSIONS Both Ahmed and Molteno implants successfully preserved visual field, although IOP control was more pronounced in the Molteno implant group.
منابع مشابه
Supra-tenon capsule placement of original Molteno vs Molteno 3 tube implants in black patients with refractory glaucoma: a single-surgeon experience.
OBJECTIVE To evaluate the efficacy of supra-Tenon capsule placement of original Molteno vs Molteno 3 tube implants (Molteno Ophthalmic, Dunedin, New Zealand) in black patients with refractory glaucoma. METHODS A retrospective study comparing the efficacy of supra-Tenon capsule placement of the original Molteno tube implant (130-mm(2) plate size) with the newer Molteno 3 tube implant (175-mm(2...
متن کاملCorneal endothelial cell changes after Ahmed valve and Molteno glaucoma implants.
BACKGROUND AND OBJECTIVE Changes in corneal endothelial cell (CEC) indices 24 months after Ahmed valve (New World Medical, Inc., Rancho Cucamonga, CA) and single-plate Molteno implants (Molteno Ophthalmic Limited, Dunedin, New Zealand) were evaluated. PATIENTS AND METHODS This cohort included Ahmed valve (29 eyes) or single-plate Molteno (28 eyes) implants. Preoperative and postoperative cent...
متن کاملUpdate on Tube-Shunt Procedures for Glaucoma
Present-day glaucoma implants, i.e., long-tube implants, were introduced by Molteno et al. in 1976 [31]. !e most commonly used implants include Molteno and Ahmed singleand doubleplate implants, and the Baerveldt and Krupin implants. All implants are long-tube implants based on the original Molteno design. !e Ahmed and Krupin implants are valved implants. !e most recent addition to tube-shunt de...
متن کاملMolteno3: Design and clinical evaluation
We describe the Molteno3 glaucoma implant, its design principles and the differences and similarities with the current generation of Molteno implant. Clinical results from 37 Molteno3 implant procedures for primary open angle glaucoma are compared with a control group of 33 pressureridge single plate Molteno implants. The results obtained in cases of primary open angle glaucoma, neovascular gla...
متن کاملOtago glaucoma surgery outcome study: comparative results for the 175-mm2 Molteno3 and double-plate molteno implants.
OBJECTIVE To evaluate the efficacy of the 175-mm2 Molteno3 implant in patients with nonneovascular glaucoma. METHODS A hospital-based, retrospective historical control comparative case series comparing results in the first 87 eyes to receive the 175-mm(2) Molteno3 implant with those in a control group of 115 eyes receiving the 274-mm(2) double-plate Molteno implant. RESULTS Success was defi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of ophthalmology
دوره 149 6 شماره
صفحات -
تاریخ انتشار 2010