Effect of Link - Beam Stiffener and Brace Flange Alignment on Inelastic Cyclic Behavior of Eccentrically Braced Frames
نویسنده
چکیده
Finite element analysis was used to investigate the effects of the misalignment of the brace flange-to-beam connection point with the link-end stiffener (referred to as the offset in the paper) on the ductility of eccentrically braced frames (EBF). The offset was speculated to be a possible reason for the unexpected EBF failures observed in the aftermath of the Christchurch earthquake series of 2010 and 2011. EBF models with different detailing at the offset area were analyzed under monotonic and cyclic displacements. Results showed severe stress and strain concentration in the offset area, preventing the EBF from developing its expected ductility, and suggested possible initiation of a failure from the part of link flange located in the offset area. Simulation using the ductile fracture model implemented in ABAQUS resulted in a fracture pattern in agreement with the actual failed EBF. Results from analyses on different detail configurations showed that removal of the offset by modifying the brace section to build an ideal case, or by a simple change in the location of the link stiffener, can mitigate the problem of possible premature failure, with the latter solution being slightly less effective but much easier to be used in practice.
منابع مشابه
Numerical study on the behavior of link-to-column connections in eccentrically braced frames
Geometry of eccentrically braced frames (EBFs) in some cases causes the connection of link beam to the column. The details of such conditions should be studied carefully due to the full plastic rotation in the link beam. In this research, the behavior of link-to-column connection is modeled and the failure modes are considered. Based on the previous researches shear link can exhibit better beha...
متن کاملTubular Links for Eccentrically Braced Frames. II: Experimental Verification
This paper describes the results of an experimental study to verify proposed design requirements for eccentrically braced frame links with hollow rectangular i.e., tubular cross sections. Twelve primary link specimens and two supplementary links that have different end connections are tested. Three cross sections and four normalized link lengths are considered. Two of the cross sections have we...
متن کاملAssessment of Seismic Behavior of Eccentrically Braced Frame with Double Vertical Link (dv-ebf)
This paper is an experimental study on the behavior of vertical shear link in the single and double configurations. There have been three specimens selected for examining the effects of different details .The first specimen was an I section with no stiffener, while the second specimen composed of I section with stiffeners designed according to AISC 2005. Third specimens were composed of two I s...
متن کاملStudy of Adding Cover—Plate Used For the Single Diagonal Eccentrically Braced Steel Frames
This paper suggested a new connection protocol, adding cover-plate between shear links and column, which was used to enhance moment and shear carrying capacity of beam, relax the restriction and assure the sufficiency development of plastic deformation of the link, and dissipate more earthquake energy. Considering the scale ratio of 1:3, the experimental data was achieved by a specimen under cy...
متن کاملStudy of an Optimum Design Method for Links
Under severe earthquakes, eccentrically braced frames might experience large inelastic deformations, and the inelastic action is restricted primarily to the ductile links. In order to study the reasonable design method for links, seventy analyses of links are conducted to investigate the effect of different flange width-thickness ratio and length, fifty links are also designed to study the infl...
متن کامل