Coupling between energy and phase in hollow-core fiber based f-to-2f interferometers.
نویسندگان
چکیده
The dependence of the carrier-envelope (CE) phase of the pulses from a hollow-core fiber on the input laser energy was studied using two f-to- 2f interferometers. The CE phase in the in-loop f-to-2f interferometer was measured with the octave spanning white-light spectrum from the hollow-core fiber, whereas the out-of-loop interferometer was based on a sapphire plate. By modulating the input power of the in-loop interferometer and measuring the out-of-loop CE phase at the same time, the coupling coefficient between the measured CE phase and the laser energy for the hollow-core fiber was determined to be 128 mrad per 1% energy change .
منابع مشابه
Gas Sensor Based on Large Hollow-Core Photonic Bandgap Fiber
One concern in using photonic band-gap fiber (PBGF) as a gas sensor is the response time. In this type of the gas sensors, response time is the time required for gas to diffuse into the hollow-core. So considering a large hollow-core PBGF (HC-PBGF), the response time can be significantly reduced. But in the large HC-PBGF, the fundamental issue is the presence of higher order modes (HOMs). Somet...
متن کاملMechanism of phase-energy coupling in f-to-2f interferometry.
White-light generation has been used widely in single-shot f-to-2f interferometers for stabilizing the carrier-envelope (CE) phase of laser amplifiers. The accuracy of the relative phase values measured by such an interferometer is affected by fluctuations in the laser pulse energy. A simple two-step model is proposed to explain the mechanism that couples the laser energy and the CE phase. The ...
متن کاملDevelopment of a Simple and Efficient Method for Preconcentration and Determination of Trace Levels of Fexofenadine in Plasma and Urine Samples
A simple, inexpensive and sensitive three-phase hollow fiber liquid-phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) with UV detection was successfully developed for determination of trace level of an anti-Histamine drug, fexofenadine, in human plasma and urine. The analyte was extracted into n-octanol that was immobilized in the wall of a porous hollow ...
متن کاملDevelopment of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design
In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...
متن کاملModeling and Simulation of CO2 Absorption Enhancement in Hollow-Fiber Membrane Contactors using CNT–Water-Based Nanofluids
Absorption of CO2 from a gas mixture containing CO2 and nitrogen by water-based CNT nanofluids in gas–liquid hollow fiber membrane contactor was modeled and solved using COMSOL Multiphysics 5.4. The model assumed partial wetting of the membrane, along with diffusion in the axial and radial directions. In addition, Brownian motion and grazing effects were both considered in the model. The main c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 17 14 شماره
صفحات -
تاریخ انتشار 2009