Missing head and color banding in low-count SPECT reconstructions.

نویسندگان

  • Robin de Nijs
  • Björn Neumann Jensen
  • Jann Mortensen
چکیده

Due to low counts in an (111)In single photon emission computed tomography (SPECT) scan, a large part of the head was missing in the reconstructed images on Philips Extended Brilliance Workspace (EBW) and IntelliSpace Portal (ISP) workstations. This problem occurred for the ordered subsets expectation maximization (OSEM) algorithm with and without resolution recovery (Astonish), but not for filtered backprojection (FBP) or maximum likelihood expectation maximization (MLEM). There were also underflow problems because the images are stored as integers resulting in a loss of intensity resolution and color banding.Philips EBW2.0 and ISP5.02 workstations upscale low-count images, but the result is not always optimal, for example, in the case of low counts in one part and more counts in another part of an image. On these workstations, the missing head artefact problem could be resolved by applying a Hann pre-filter (with a cutoff at the Nyquist frequency, which only influences the filtering) in the reconstruction process. Upscaling of the projection data prior to reconstruction did not recover the head in the images, neither did limiting the reconstructed volume to the low-count part of interest.Underflow problems were partially solved by the new version 2.0 of the Philips EBW and ISP stations, although situations could arise where underflow still poses a problem. A solution for the underflow problems is to upscale the raw projection data before reconstruction. While this results in a pure upscaling of the FBP reconstruction, the effect in iterative statistical reconstruction is not only upscaling of the intensities because the assumption of Poisson statistics of the data is violated. However, the influence of this last matter seems limited.Reconstruction of studies with low counts in relevant areas should be performed with care. Reconstruction artefacts and scaling issues can easily arise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uncertainty Estimation for Bayesian Reconstructions from Low-Count SPECT Data

Bayesian analysis is especially useful to apply to lowcount medical imaging data, such as gated cardiac SPECT, because it allows one to solve the nonlinear, ill-posed, inverse problems associated with such data. One advantage of the Bayesian approach is that it quantifies the uncertainty in estimated parameters through the posterior probability. We compare various approaches to exploring the un...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

Scatter and attenuation correction for brain SPECT using attenuation distributions inferred from a head atlas.

UNLABELLED Sequential transmission scanning (TS)/SPECT is impractical for neurologically impaired patients who are unable to keep their heads motionless for the extended duration of the combined scans. To provide an alternative to TS, we have developed a method of inferring-attenuation distributions (IADs), from SPECT data, using a head atlas and a registration program. The validity of replacin...

متن کامل

Color filter arrays based on mutually exclusive blue noise patterns

The ordered color filter arrays (CFA) used in single-sensor, color digital still cameras introduce distracting color artifacts. These artifacts are due to the phase-shifted, aliased signals introduced by the sparse sampling by the CFAs. This work reports the results of an investigation on the possibility of using random patterns as a CFA for single-sensor, digital still cameras. From a single b...

متن کامل

Quantification of Partial Volume Effects in Salivary Glands SPECT Images after Radiation Therapy of Head and Neck Tumors

Introduction: Radical radiation therapy of head and neck cancers may injure the salivary glands and reduce their function. Single-photon emission computed tomography (SPECT) images maybe used to evaluate function post-therapy. However, accurate quantification is hindered by the partial volume effects (PVEs). The present study involved the introduction of a PVEs quantif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • EJNMMI physics

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2014