Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model.

نویسندگان

  • Andrew Mahar
  • Jeffrey Tamborlane
  • Richard Oka
  • James Esch
  • Robert A Pedowitz
چکیده

PURPOSE The purpose of this study was to determine biomechanical differences in cyclic elongation and ultimate strength between double-row rotator cuff repair and single-row repair for partial rotator cuff repairs. METHODS We randomly assigned 18 immature bovine specimens (aged 12 to 16 weeks) to 3 repair groups (6 per group). A 1 x 2-cm defect was created at the infraspinatus tendon insertion site. Two suture anchors were implanted 1 cm apart at the anatomic insertion area for the lateral row. Two suture anchors were implanted 1 cm medial to the lateral row and 1 cm apart from each other for the medial row. Repair groups were constructed as follows: single-row repair with double-loaded suture anchors (group 1), double-row repair with single-loaded medial row and double-loaded lateral row (group 2), and double-row repair with single-loaded medial row and single-loaded lateral row (group 3). Specimens were cyclically loaded from 10 N to 90 N for 500 cycles and then loaded at 0.5 mm/s to failure. Data for cyclic elongation, with loads at 3 mm, 5 mm, and 10 mm, were analyzed via a 1-way analysis of variance (P < .05). RESULTS There were no significant differences for peak elongation after cyclic loading between groups. There were no significant differences between repair groups for loads at 3 mm, 5 mm, and 10 mm of elongation. Constructs typically failed by knot slippage (83%), with a single sample having tendon-suture failure (17%). CONCLUSIONS Double-row repair did not show a biomechanical advantage compared with single-row repair. With this result in mind, the theoretic advantage of a potentially larger footprint must be balanced against the added surgical time, complexity, and cost of double-row repair. CLINICAL RELEVANCE Arthroscopic surgeons should choose the best form of fixation for a given patient, without undue emphasis on single-row repair versus double-row repair. The clinical and biologic impact of footprint restoration was not addressed in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arthroscopic single-row versus double-row suture anchor rotator cuff repair.

BACKGROUND Recurrent defects after open and arthroscopic rotator cuff repair are common. Double-row repair techniques may improve initial fixation and quality of rotator cuff repair. PURPOSE To evaluate the load to failure, cyclic displacement, and anatomical footprint of 4 arthroscopic rotator cuff repair techniques. HYPOTHESIS Double-row suture anchor repair would have superior structural...

متن کامل

Does the literature support double-row suture anchor fixation for arthroscopic rotator cuff repair? A systematic review comparing double-row and single-row suture anchor configuration.

PURPOSE The purpose of this study was to compare the clinical outcome of single-row (SR) and double-row (DR) suture anchor fixation in arthroscopic rotator cuff repair with a systematic review of the published literature. METHODS We searched all published literature from January 1966 to December 2008 using Medline, CINAHL (Cumulative Index to Nursing and Allied Health Literature), and the Coc...

متن کامل

Impingement syndrome of the shoulder following double row suture anchor technique for arthroscopic rotator cuff repair: a case report

INTRODUCTION Arthroscopic repair of the rotator cuff is a demanding surgery. Accurate placement of anchors is key to success. CASE PRESENTATION A 38-year-old woman received arthroscopic repair of her rotator cuff using a double row suture anchor technique. Postoperatively, she developed impingement syndrome which resulted from vertical displacement of a suture anchor once the shoulder was mob...

متن کامل

Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model.

BACKGROUND To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal. The hypothesis is there is no significant difference in the biomecha...

متن کامل

Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique

BACKGROUND Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. METHODS The preferred technique for rotator cuff repair of the senior author was reviewed and described in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 23 12  شماره 

صفحات  -

تاریخ انتشار 2007