Usefulness of C-stopper Coil for Neurointervention
نویسندگان
چکیده
C-stopper coil (CSC) which are available for 0.018-inch inner diameter microcenter have been used for neurointervention such as transarterial embolization (TAE) of feeding artery. Although various shapes of pushable microcoils have been developed, microcoils are usually short to embolize the lesion and require lots of coils. The most specific feature of CSC is the extended length of 18 cm. To evaluate the usefulness of CSC, we reviewed our experience of CSC. Neurointervention using CSC was performed for 28 patients (31 treatments). Intervention procedures were TAE for dural arteriovenous fistula (AVF)(n = 15), transvenous embolization for dural AVF (n = 4), parent artery occlusion for cerebral aneurysm, dissection and carotid-cavernous fistula (n = 8), TAE for epistaxis (n = 2), and preoperative embolization for tumor (n = 2). CSCs were deployed with push technique through microcatheter. CSCs were successfully placed into the lesion namely feeding artery, venous sinus, parent artery of aneurysm, or dissection. There were no major technical complications resulting in morbidity. Postoperative course was uneventful. No recanalization of the occluded vessel occurred during follow-up. Use of CSCs was safe and feasible for embolization of cerebrovascular lesion.
منابع مشابه
Endovascular Coil Trapping of a Ruptured Dissecting Aneurysm of the Vertebral Artery Using Detachable Coils and Micro-Tornado® Coils
We experienced a patient with a ruptured dissecting aneurysm of the vertebral artery who was treated by trapping of the lesion using Guglielmi detachable coils (GDCs) with micro-tornado® coils (MTCs). An 80-year-old male was transferred with a ruptured left vertebral artery dissecting aneurysm (VADA). The dissected portion of the vertebral artery was effectively trapped using GDCs and MTCs. The...
متن کاملImproving Forward Infusion Pressure during Brain Tumor Embolization with the Double Catheter and Coil Technique
Endovascular embolization or embosurgery of brain tumors can be used to reduce neoplasm vascularity prior to surgical resection. Two challenges with embosurgery relate to insufficient perfusion pressure into the tumor and inadvertent escape of infused agents into parenchymal branches of the adjacent brain. This report describes a multi-catheter and coil technique to improve tumor perfusion and ...
متن کاملDelayed Herniation of Coil Loop and Spontaneous Reposition in a Superior Cerebellar Artery Aneurysm
Herniation of coil loops into the parent artery is one of the complications of endovascular embolization with detachable coils. In this clinical setting, we cannot predict the consequence of the herniated coil loop. We report an unusual case of a superior cerebellar artery (SCA) aneurysm with delayed coil herniation into the basilar artery and spontaneous reposition into the SCA.
متن کاملManual Aspiration Technique to Retrieve a Prematurely Detached Coil during Cerebral Aneurysm Embolization
Coil herniation, premature deployment, and fracture are procedure associated complications of endovascular aneurysm embolization that optimally necessitate coil retrieval when feasible. Several published techniques describe different strategies for managing coil complications including various snare retrieval devices, alligator retrieval devices, stent fixation, and open surgical resection of c...
متن کاملDiffuse Alveolar Hemorrhage in Patients Undergoing Neurointervention: A Case Report
INTRODUCTION Diffuse alveolar hemorrhage (DAH) is a very rare complication but acute and life-threatening event. Clopidogrel has generally administered for neurointerventional surgery, but there were no reports of DAH related to clopidogrel in patients undergoing neurointervention. CASE PRESENTATION A 70-year-old male presented with DAH associated with clopidogrel after transfemoral cerebral ...
متن کامل