Usefulness of three-dimensional reconstruction for interpretation and quantitative analysis of intracoronary ultrasound during stent deployment.
نویسندگان
چکیده
We examined 49 coronary stents in 33 patients after angiographically guided optimization of the deployment by intracoronary ultrasound, and compared the findings of a conventional 2-dimensional analysis approach with the results obtained from an automatic lumen recognition provided by a 3-dimensional reconstruction system. The automatic lumen analysis demonstrated that only 15 stents (31%) fulfilled defined ultrasound criteria of adequate stent deployment, and that 5 of these cases were missed by the conventional approach, which systematically overestimated the dimensions of the minimal stent lumen.
منابع مشابه
Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملThree dimensional reconstruction of cross sectional intracoronary ultrasound: clinical or research tool?
Correspondence to: Dr J RT C Roelandt, Division of Cardiology, Thoraxcenter BD 408, University Hospital Dijkzigt, PO Box 1738 DR Rotterdam, The Netherlands. In a recent survey conducted in 30 centres with large experience in intracoronary ultrasound, three dimensional reconstruction of intracoronary ultrasound was ranked as the technical development with the lowest priority,' suggesting that it...
متن کاملModeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code
Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...
متن کاملElectrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification.
OBJECTIVE This study evaluates the feasibility, reliability and reproducibility of electrocardiogram (ECG)-gated intravascular ultrasound (IVUS) image acquisition during automated transducer withdrawal and automated three-dimensional (3D) boundary detection for assessing on-line the result of coronary stenting. BACKGROUND Systolic-diastolic image artifacts frequently limit the clinical applic...
متن کاملCompliance of a cobalt chromium coronary stent alloy – the COVIS trial
BACKGROUND Cobalt chromium coronary stents are increasingly being used in percutaneous coronary interventions. There are, however, no reliable data about the characteristics of unfolding and visibility of this stent alloy in vivo. The aim of this study is to compare cobalt chromium coronary stents with conventional stainless steel stents using intracoronary ultrasound. METHODS Twenty de novo ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 77 9 شماره
صفحات -
تاریخ انتشار 1996