Experimental model to evaluate mechanical closure resistance of sutureless vitrectomy sclerotomies using pig eyes.
نویسندگان
چکیده
PURPOSE The purpose of this study was to report a novel model for comparing mechanical resistance to intraocular pressure (IOP) increases with 23-gauge (23G) and 25G transconjunctival sutureless vitrectomy (TSV) sclerotomies in the immediate postoperative period using an experimental model of a vitrectomized eye. METHODS This was a prospective, experimental, randomized, and observer-masked experimental study in which TSV 23G and 25G oblique sclerotomies, performed in same cadaveric pig eye, were subject to an increase in IOP. Mechanical resistance was determined by the resistance to intraocular fluid leak through the sclerotomy. The simultaneous use of the different sclerotomy diameters in the same eye avoided interindividual scleral resistance differences. RESULTS This animal model allowed comparison of the effect of different sclerotomy diameters (23G and 25G) on incisional mechanical resistance. One hundred twenty eyes were included. In 60.7% of cases, the 23G sclerotomy first allowed intraocular fluid escape (leaked; P = 0.02). When comparing opening pressure values, 23G sclerotomies leaked at significantly lower pressure levels than 25G sclerotomies (P < 0.0001); 53% of the 25G incisions but only 16% of 23G incisions opened at pressure levels greater than 120 mm Hg. CONCLUSIONS Oblique 23G sutureless sclerotomies offer less mechanical resistance to increases in IOP than do 25G sclerotomies. This animal model may become the basis for future studies to evaluate the advantages of using other types of incision or other surgical tools on sclerotomy closure capacity.
منابع مشابه
Influence of incisional vitreous incarceration in sclerotomy closure competency after transconjunctival sutureless vitrectomy.
PURPOSE To evaluate the influence that vitreous incarceration may exert on the presence of postoperative conjunctival blebs over sclerotomies after transconjunctival sutureless vitrectomy (TSV). Blebs are formed by incisional leakage due to incompetent closure. METHODS Experimental study in which 23-gauge TSV was performed in 146 cadaveric pig eyes. Once the vitrectomy was finished, triamcino...
متن کاملInfluence of sclerotomy use on vitreous incarceration in an experimental model of vitrectomized eye
PURPOSE To evaluate the influence of sclerotomy use during vitrectomy (vitreous cutter, illumination probe, or infusion-line entrance) on postoperative vitreous incarceration using an experimental model of vitrectomized eye. MATERIALS AND METHODS Experimental, randomized, and observer-masked study in which 23-gauge transconjunctival sutureless vitrectomy was performed in cadaveric pig eyes. P...
متن کاملInfluence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study
BACKGROUND Characteristic complications have been reported for transconjunctival sutureless vitrectomy, such as postoperative sclerotomy leakage and postoperative hypotony. Particular attention to sclerotomy closure is required in cases of silicone oil tamponade, because postoperative supplementation of silicone oil implies reoperation, whereas postoperative supplement of gas is comparatively e...
متن کاملPolyethylene Glycol-Based Synthetic Hydrogel Sealant for Closing Vitrectomy Wounds: An In Vivo and Histological Study
PURPOSE We conducted an in vivo study using Dutch pigmented rabbit eyes to test the usefulness of polyethylene glycol (PEG) sealant for the closure of sutureless sclerotomies in microincisional vitrectomy surgery (MIVS). METHODS Three-port, 23-gauge vitrectomy was performed on rabbit eyes. After air leakage was confirmed by the application of 0.625% povidone-iodine at the sclerotomy site, PEG...
متن کاملThe Effect of Port Geometry on Vitrectomy: A Performance Analysis of Custom Probes Through Water and Tissue Removal Rates, Surgical Evaluation, and High-Speed Video
Purpose: A recent change in pars plan vitrectomy (PPV) has been the advent of smaller gauge “sutureless” instrumentation. Sutureless systems are designed to create selfsealing and leak free sclerotomies. This study’s purpose was to evaluate sutureless 23 gauge (23G) wound integrity via ultrasonographic, photographic, and tonographic techniques using a retrospective case series analysis. Method:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 7 شماره
صفحات -
تاریخ انتشار 2011