Relationship between field walking tests and incremental cycle ergometry in COPD.

نویسندگان

  • Nia Luxton
  • Jennifer A Alison
  • Judy Wu
  • Martin G Mackey
چکیده

BACKGROUND AND OBJECTIVE Cycle ergometer training is an important component of pulmonary rehabilitation for patients with COPD. However, incremental cycle tests from which individualized cycle training intensity can be prescribed may not be readily available to clinicians. The aims of the study were to (i) investigate the physiological and psychophysical responses to the 6-min walk test (6MWT), incremental shuttle walk test (ISWT) and cycle ergometer test (CET); and (ii) determine whether the distance walked in either the 6MWT or the ISWT could be used to estimate peak work rate on a cycle ergometer. METHODS A repeated measures study was undertaken in COPD patients in a stable condition. The 6MWT, ISWT and CET were performed in random order, and physiological responses, rate of perceived exertion and dyspnoea were measured. RESULTS Twenty-two patients with COPD completed the study. There was no significant difference in peak oxygen uptake between the 6MWT, ISWT and CET. The significant correlation between the 6MWD and incremental shuttle walk distance with peak watts on the CET (r = 0.63, P = 0.002 and r = 0.75, P < 0.001, respectively) was strengthened by the inclusion of weight, age and gender (r = 0.89 P = 0.001 and r = 0.91, P < 0.001). Bland-Altman analysis demonstrated a strong agreement between peak work rate measured on the CET and that estimated from either the 6MWT or the ISWT. CONCLUSIONS The significant relationships found between the three exercise tests, and the regression equations predicting peak work rate on the CET from the 6MWT or the ISWT, may allow for the estimation of intensity of cycle exercise training from walk tests in COPD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing peak and submaximal cardiorespiratory responses during field walking tests with incremental cycle ergometry in COPD.

BACKGROUND AND OBJECTIVE Field and laboratory-based tests are used to measure exercise capacity in people with COPD. A comparison of the cardiorespiratory responses to field tests, referenced to a laboratory test, is needed to appreciate the relative physiological demands. We sought to compare peak and submaximal cardiorespiratory responses to the 6-min walk test, incremental shuttle walk test ...

متن کامل

Peak exercise capacity estimated from incremental shuttle walking test in patients with COPD: a methodological study

BACKGROUND In patients with COPD, both laboratory exercise tests and field walking tests are used to assess physical performance. In laboratory tests, peak exercise capacity in watts (W peak) and/or peak oxygen uptake (VO2 peak) are assessed, whereas the performance on walking tests usually is expressed as distance walked. The aim of the study was to investigate the relationship between an incr...

متن کامل

Characteristics and determinants of endurance cycle ergometry and six-minute walk distance in patients with COPD

BACKGROUND Exercise tolerance can be assessed by the cycle endurance test (CET) and six-minute walk test (6MWT) in patients with Chronic Obstructive Pulmonary Disease (COPD). We sought to investigate the characteristics of functional exercise performance and determinants of the CET and 6MWT in a large clinical cohort of COPD patients. METHODS A dataset of 2053 COPD patients (43% female, age: ...

متن کامل

The effects of oxitropium bromide on exercise performance in patients with stable chronic obstructive pulmonary disease. A comparison of three different exercise tests.

The purpose of the present study was to compare the characteristics of three different exercise tests in evaluating the effects of oxitropium bromide on exercise performance. Thirty-eight males with stable chronic obstructive pulmonary disease (COPD) (FEV(1) = 40.8 +/- 16.5% predicted; mean +/- SD) completed randomized, double-blind, placebo-controlled, crossover studies for each exercise test....

متن کامل

Rating of Perceived Exertion as an Indicator of Exercise Intensity in Paraplegics

Background: Energy expenditure is of paramount importance in the assessment of usefulness of wheelchair for paraplegics. Despite widespread recognition of problems associated with currently available mobility systems for persons with spinal cord injuries, development of more efficient systems has been slow.  Lack of a suitable and simple technique for the assessment of energy expenditure in par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respirology

دوره 13 6  شماره 

صفحات  -

تاریخ انتشار 2008