Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

نویسندگان

  • Timothy M Bateman
  • Gary V Heller
  • A Iain McGhie
  • John D Friedman
  • James A Case
  • Jan R Bryngelson
  • Ginger K Hertenstein
  • Kelly L Moutray
  • Kimberly Reid
  • S James Cullom
چکیده

BACKGROUND Although single photon emission computed tomography (SPECT) and positron emission tomography (PET) myocardial perfusion imaging (MPI) have evolved considerably over the last decade, there is no recent comparison of diagnostic performance. This study was designed to assess relative image quality, interpretive confidence, and diagnostic accuracy by use of contemporary technology and protocols. METHODS AND RESULTS By consensus and without clinical information, 4 experienced nuclear cardiologists interpreted 112 SPECT technetium-99m sestamibi and 112 PET rubidium-82 MPI electrocardiography (ECG)-gated rest/pharmacologic stress studies in patient populations matched by gender, body mass index, and presence and extent of coronary disease. The patients were categorized as having a low likelihood for coronary artery disease (27 in each group) or had coronary angiography within 60 days. SPECT scans were acquired on a Cardio-60 system and PET scans on an ECAT ACCEL scanner. Image quality was excellent for 78% and 79% of rest and stress PET scans, respectively, versus 62% and 62% of respective SPECT scans (both p<.05). An equal percent of PET and SPECT gated images were rated excellent in quality. Interpretations were definitely normal or abnormal for 96% of PET scans versus 81% of SPECT scans (p=.001). Diagnostic accuracy was higher for PET for both stenosis severity thresholds of 70% (89% vs 79%, p=.03) and 50% (87% vs 71%, p=.003) and was higher in men and women, in obese and nonobese patients, and for correct identification of multivessel coronary artery disease. CONCLUSION In a large population of matched pharmacologic stress patients, myocardial perfusion PET was superior to SPECT in image quality, interpretive certainty, and diagnostic accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

Gated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease

Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups:  38 patients wit...

متن کامل

Assessment of contractile response to dobutamine stress by means of ECG-gated myocardial SPECT: comparison with myocardial perfusion and fatty acid metabolism.

UNLABELLED The present study assessed left ventricular performance during dobutamine stress measured using gated SPECT, and compared the results to myocardial perfusion and fatty acid metabolism. METHODS Thirty-six patients with myocardial infarction given (99m)Tc-sestamibi or (99m)Tc-tetrofosmin were examined by gated SPECT at rest and during dobutamine stress (4-20 microg x kg(-1) x min(-1)...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 2006