Specific detection of primary amines in the effluent of a gas-chromatographic column by on-line measurement of fluorescence.

نویسندگان

  • F Chow
  • A Karmen
چکیده

Compounds with primary amino groups react with o-phthalaldehyde in solution to yield highly fluorescent products. This reaction is now in wide use for detecting amino acids and amines in liquid-chromatography effluents. We report here a method for using o-phthalaldehyde to detect primary amines in the effluent of a gas-liquid-chromatographic column. The effluent gas, nominally 20 mL/min, is delivered to a scrubber consisting of a small-bore, simulated capillary chromatographic column that is simultaneously supplied with 1 mL/min of the reagent solution. The liquid effluent of the scrubber, separated from the gas, is drawn through the flow cell of a fluorometer. Short-chain amines and ammonia were quantitatively scrubbed. The response of the fluorometer was directly proportional to the number of nanomoles injected into the column. Less than a nanomole of amine was detectable. Comparison of results with those from a hydrogen flame-ionization detector showed minimal additional peak broadening or compromise of resolution. These results demonstrate the feasibility of using highly specific, as well as sensitive, liquid-chromatographic detection methods for gas-liquid chromatography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

A Sensitive Liquid Chromatographic Method for the Analysis of Clarithromycin with Pre-Column Derivatization: Application to a Bioequivalence Study

Objective(s) A sensitive liquid chromatographic method for the analysis of clarithromycin- a macrolide antibiotic- in human serum, using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. Materials and Methods The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes...

متن کامل

Automated pre-column derivatization of amines in biological samples with dansyl chloride and with or without post-column chemiluminescence formation by using TCPO-H2O2.

On-line automation of two different liquid chromatographic procedures, a pre-column derivatization system and a pre- and post-column system, in order to generate chemiluminescence is reported. Dansyl chloride (Dns-Cl) was used as a pre-column reagent to form fluorophores and bis(2,4,6-trichlorophenyl) oxalate (TCPO) and hydrogen peroxide (H2O2) as a post-column reagent to generate chemiluminesc...

متن کامل

High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma

The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 10  شماره 

صفحات  -

تاریخ انتشار 1980