A Preliminary Comparison of MCNP6 Delayed Neutron Emission from
نویسندگان
چکیده
A Description of the Experiment The DNC system at RMCC uses the SLOWPOKE-2 reactor [2] as a source of neutrons. Samples containing 235 U were prepared as acidified aqueous solutions from certified reference standards (natural U standard CRM 4321C, NIST, Gaithersburg, MD, and depleted U standard CRM U005A 0.5064 ± 0.0003 atom% U, New Brunswick Laboratory, Argonne, IL). Each solution was contained in heat sealed small polyethylene (PE) vials (LA Packaging, Yorba Linda, CA) with a nominal solution of 1 mL. To minimize the potential of solution leakage into the pneumatic tubing of the system, secondary containment was achieved using heat sealed 7 mL polyethylene vials (LA Packaging). By irradiating the inner and outer polyethylene vials without any fissile sample, the vials have been found to contain no impurities that contribute to the overall neutron count rate recorded by the DNC system [3]. Samples containing the fissile content were sent to an irradiation site inside the SLOWPOKE-2 beryllium reflector where they were exposed to a predominately thermal neutron spectrum of 5.6e11 cm -2 s -1 (±5%) for durations up to 60 s. After the samples were irradiated they were automatically sent, via pneumatic transfer system, to the neutron counting arrangement. This consisted of six 304 Stainless Steel (S.S.); Reuter Stokes 3 He detectors (RSP4-1613-202, GE Energy, Twinsburg, OH) embedded in a paraffin moderator. Samples were located at the center of the hexagonal detector array. A delay time of 3 s was employed to account for sample travel time from the irradiation site and the commencement of the delayed neutron count. Delayed neutrons were recorded as a function of time, in 0.5 s intervals.
منابع مشابه
Optimization of 241Am-Be emission direction in neutron porosity tools for improving the precision in determining the porosity in calcite formation
Investigation of Hydrocarbon reservoir is important, so it is essential to predict and explore them precisely. One of the methods is well logging, which can transfer the probe or tool in the well to measure one or more characteristics. Nuclear well logging includes radioisotope source and at least one detector. In this work, emission direction of neutrons from the 241Am-Be neutron source toward...
متن کاملThe neutron long counter NERO for studies of b delayed neutron emission in the r-process
The neutron long counter NERO was built at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University, for measuring b delayed neutron-emission probabilities. The detector was designed to work in conjunction with a b delay implantation station, so that b decays and b delayed neutrons emitted from implanted nuclei can be measured simultaneously. The high efficiency of ab...
متن کاملInvestigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator
Introduction: This study aimed to measure the neutron contamination of flattening filter (FF) and flattening filter-free (FFF) 10-MV photon beams delivered by the Elekta InfinityTM accelerator. Material and Methods: The photoneutron spectrum produced by the Linac head was evaluated using a Monte Carlo (MC) simulation. The geometry ...
متن کاملStudying Transition Behavior of Neutron Point Kinetics Equations Using the Lyapunov Exponent Method
The neutron density is one of the most important dynamical parameters in a reactor. It is directly related to the control and stability of the reactor power. Any change in applied reactivity and some of dynamical parameters in the reactor causes a change in the neutron density. Lyapunov exponent method is a powerful tool for investigating the range of stability and the transient behavior of the...
متن کاملA Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom
Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...
متن کامل