A liquid-crystal-based DNA biosensor for pathogen detection

نویسندگان

  • Mashooq Khan
  • Abdur Rahim Khan
  • Jae-Ho Shin
  • Soo-Young Park
چکیده

A liquid-crystal (LC)-filled transmission electron microscopy (TEM) grid cell coated with the cationic surfactant dodecyltrimethylammonium bromide (DTAB), to which a single-stranded deoxyribonucleic acid probe (ssDNAprobe) was adsorbed at the LC/aqueous interface (TEMDTAB/DNA), was applied for the highly specific detection of target DNA molecules. The DTAB-coated E7 (used LC mixture) in the TEM grid (TEMDTAB) exhibited a homeotropic orientation, and changed to a planar orientation upon adsorption of the ssDNAprobe. The TEMDTAB/DNA was then exposed to complementary (target) ssDNA, which resulted in a planar-to-homeotropic configurational change of E7 that could be observed through a polarized optical microscope under crossed polarizers. The optimum adsorption density (2 μM) of ssDNAprobe enabled the detection of ≥0.05 nM complementary ssDNA. This TEMDTAB/DNA biosensor could differentiate complementary ssDNA from mismatched ssDNA as well as double-stranded DNA. It also successfully detected the genomic DNAs of the bacterium Erwinia carotovora and the fungi Rhazictonia solani. Owe to the high specificity, sensitivity, and label-free detection, this biosensor may broaden the applications of LC-based biosensors to pathogen detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gold nanoparticle based signal enhancement liquid crystal biosensors for DNA hybridization assays.

A novel signal enhanced liquid crystal biosensor based on using AuNPs for highly sensitive DNA detection has been developed. This biosensor not only significantly decreases the detection limit, but also offers a simple detection process and shows a good selectivity to distinguish perfectly matched target DNA from two-base mismatched DNA.

متن کامل

DNA Biosensor for Determination of 5-Fluorouracil based on Gold Electrode Modified with Au and Polyaniline Nanoparticles and FFT Square Wave Voltammetry

In the present study, a new biosensor for 5-Fluorouracil was described using modified goldelectrode and Fast Fourier transform square wave voltammetry (FFT SWV). Calf thymus DNAimmobilization was on a gold electrode decorated with polyaniline and gold nanoparticles. Theelectrochemical characteristics of the electrodes were investigated by cyclic voltammetry, andelectroch...

متن کامل

A Portable Automatic Endpoint Detection System for Amplicons of Loop Mediated Isothermal Amplification on Microfluidic Compact Disk Platform

In recent years, many improvements have been made in foodborne pathogen detection methods to reduce the impact of food contamination. Several rapid methods have been developed with biosensor devices to improve the way of performing pathogen detection. This paper presents an automated endpoint detection system for amplicons generated by loop mediated isothermal amplification (LAMP) on a microflu...

متن کامل

اندازه گیری هیدروکربن های آروماتیک چند حلقه ای در منابع آبی با استفاده از زیست حسگر الکتروشیمیایی (DNA)

Background and Objectives: Polycyclic aromatic hydrocarbons (PAHs) are widespread environmental contaminants in aquatic environments. These contaminants are generated through oil spills, manufactory processes, and industrial wastes or naturally through the incomplete combustion of coal, oil, gas, and wood waste. Most of these compounds are noted as carcinogenic and mutagenic. Therefore, detecti...

متن کامل

Fabrication of a Voltammetric Biosensor in Combination with Enzyme-linked Immunosorbent Assay to Detect Aflatoxin M1 in Milks

Background and Objectives: Aflatoxin M1 is one the most important mycotoxin contaminants of milks. Various methods have been described to detect aflatoxins in milks, including chromatography, enzyme-linked immunosorbent assay and colorimetry. Regarding high sensitivity of electrochemical sensor based methods, the aim of the present study was to fabricate an accurate sensitive voltametric biosen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016