Interaliasing distance of the flow convergence surface for determining mitral regurgitant volume: a validation study in a chronic animal model.

نویسندگان

  • M Sitges
  • M Jones
  • T Shiota
  • D L Prior
  • J X Qin
  • H Tsujino
  • F Bauer
  • Y J Kim
  • D Deserranno
  • N L Greenberg
  • L A Cardon
  • A D Zetts
  • M J Garcia
  • J D Thomas
چکیده

OBJECTIVES We aimed to validate a new flow convergence (FC) method that eliminated the need to locate the regurgitant orifice and that could be performed semiautomatedly. BACKGROUND Complex and time-consuming features of previously validated color Doppler methods for determining mitral regurgitant volume (MRV) have prevented their widespread clinical use. METHODS Thirty-nine different hemodynamic conditions in 12 sheep with surgically created flail leaflets inducing chronic mitral regurgitation were studied with two-dimensional (2D) echocardiography. Color Doppler M-mode images along the centerline of the accelerating flow towards the mitral regurgitation orifice were obtained. The distance between the two first aliasing boundaries (interaliasing distance [IAD]) was measured and the FC radius was mathematically derived according to the continuity equation (R(calc) = IAD/(1 - radicalv(1)/v(2)), v(1) and v(2) being the aliasing velocities). The conventional 2D FC radius was also measured (R(meas)). Mitral regurgitant volume was then calculated according to the FC method using both R(calc) and R(meas). Aortic and mitral electromagnetic (EM) flow probes and meters were balanced against each other to determine the reference standard MRV. RESULTS Mitral regurgitant volume calculated from R(calc) and R(meas) correlated well with EM-MRV (y = 0.83x + 5.17, r = 0.90 and y = 1.04x + 0.91, r = 0.91, respectively, p < 0.001 for both). However, both methods resulted in slight overestimation of EM-MRV (Delta was 3.3 +/- 2.1 ml for R(calc) and 1.3 +/- 2.3 ml for R(meas)). CONCLUSIONS Good correlation was observed between MRV derived from R(calc) (IAD method) and EM-MRV, similar to that observed with R(meas) (conventional FC method) and EM-MRV. The R(calc) using the IAD method has an advantage over conventional R(meas) in that it does not require spatial localization of the regurgitant orifice and can be performed semiautomatedly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler evaluation of severity of mitral regurgitation: relation to pulmonary venous blood flow patterns in an animal study.

OBJECTIVES This study examined the influence of regurgitant volume on pulmonary venous blood flow patterns in an animal model with quantifiable mitral regurgitation. BACKGROUND Systolic pulmonary venous blood flow is influenced by atrial filling and compliance and ventricular output and by the presence of mitral regurgitation. The quantitative severity of the regurgitant volume itself is diff...

متن کامل

Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.

BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...

متن کامل

Color Doppler regurgitant jet area for evaluating eccentric mitral regurgitation: an animal study with quantified mitral regurgitation.

OBJECTIVES The purpose of the present study was to rigorously evaluate the accuracy of the color Doppler jet area planimetry method for quantifying chronic mitral regurgitation. BACKGROUND Although the color Doppler jet area has been widely used clinically for evaluating the severity of mitral regurgitation, there have been no studies comparing the color jet area with a strictly quantifiable ...

متن کامل

Physiologic Application of the Proximal Flow Convergence Method: Clinical Data and Experimental Testing

Background The proximal flow convergence method, a quantitative color Doppler flow technique, has been validated recently for calculating regurgitant flow and orifice area. We investigated the potential of the method as a tool to study different pathophysiological mechanisms of mitral valve incompetence by assessing the time course of regurgitant flow and orifice area and analyzed the implicati...

متن کامل

Mitral valve prolapse with mid-late systolic mitral regurgitation: pitfalls of evaluation and clinical outcome compared with holosystolic regurgitation.

BACKGROUND Mitral regurgitation (MR) of mitral valve prolapse predominates in late systole but may be holosystolic or purely mid-late systolic, but the impact of MR timing on MR left ventricular and left atrial consequences and outcome is unknown. Whether effective regurgitant orifice (ERO) by the flow convergence method is similarly linked to outcome in mid-late systolic MR and holosystolic MR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 2001