Preliminary evaluation of image reconstruction by ordered-subset expectation maximization in thallium-201 lung scintigraphy.

نویسندگان

  • Jingming Bai
  • Kunihiko Yokoyama
  • Seigo Kinuya
  • Kenichi Nakajima
  • Masato Yamada
  • Kenji Ichiyanagi
  • Takatoshi Michigishi
  • Norihisa Tonami
چکیده

OBJECTIVES We observed whether clearer tumor delineation and greater tumor to non-tumor (T/N) count ratios could be obtained using an iterative ordered-subsets expectation maximization (OSEM) algorithm than conventional filtered-back projection algorithm (FBP) in the image reconstruction of thallium-201 (201Tl) lung scintigraphy. METHODS In 29 patients with lung cancer and phantom studies, tomograms were reconstructed using FBP and OSEM algorithms, with and without a prefilter (Butterworth filter: BW), whose cut-off frequencies were 0.10 cycles/pixel for FBP and 0.10 and 0.17 cycles/pixel for OSEM. Visual interpretation and tumor to non-tumor (T/N) count ratios were obtained and compared. RESULTS Without a prefilter, T/N ratios from OSEM and FBP were 1.89 +/- 0.31 (early) and 2.00 +/- 0.54 (late) for OSEM, 1.90 +/- 0.33 (early) and 2.05 +/- 0.59 (late) for FBP, respectively. The OSEM reconstruction without prefiltering showed clearer tumor contours than FBP without a prefilter. Incorporation of BW showed visually low-noised images but decreased T/N ratios in both reconstructions with BW (0.10 cycles/pixel). No greater T/N ratios were obtained by OSEM than FBP, with or without prefiltering. With BW with a cut-off frequency of 0.17 cycles/pixel, the same T/N ratios as those without BW were obtained. The tumor model sized 0.9 cm in the phantom study was invisible in both OSEM and FBP reconstructions without a prefilter, but visible with a prefilter. The influence of prefiltering on T/N ratios was also observed in phantom studies. CONCLUSIONS Visually improved tumor delineation could be obtained in OSEM reconstruction without a prefilter as compared to FBP reconstruction without a prefilter for tumors greater than 2 cm. Prefiltering should be incorporated into OSEM reconstruction in diagnosing small tumors. However, the influence of prefilter (BW) setting on semi-quantitative interpretation needs further discussion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification and optimisation of lung ventilation SPECT images

................................................................................................................... 1 SAMMANFATTNING ................................................................................................... 3 LIST OF PAPERS ........................................................................................................... 5 ABBREVIATIONS ..........................

متن کامل

Evaluation of list-mode ordered subset expectation maximization image reconstruction for pixelated solid-state compton gamma camera with large number of channels

The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated solid-state technology for nuclear medicine applications. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 106). For Compton camera, especially with a large numbe...

متن کامل

Evaluation of the role of system matrix in SPECT images reconstructed by OSEM technique

  Introduction: Ordered subset expectation maximization (OSEM), is an effective iterative method for SPECT image reconstruction. The aim of this study is the evaluation of the role of system matrix in OSEM image reconstruction method using four different physical beam radiation models with three detection configurations. Methods: SPECT was done with an arc of 180 deg...

متن کامل

Thallium-201 scintigraphy in the evaluation of graft dysfunction in lung transplantation. Newark Beth Israel Medical Center Lung Transplant Group.

The object of this study was to evaluate graft dysfunction utilizing thallium-201 scintigraphy in patients who had undergone lung transplantation. We studied 11 patients who had undergone single-lung transplantation and had 44 evaluations for suspected graft dysfunction. All evaluations included a lung thallium-201 scan and chest radiography. In addition, 42 transbronchial biopsies, 19 gallium-...

متن کامل

Single Photon Imaging and Instrumentation

Abbreviations 2D, 3D 2-dimensional, 3-dimensional CZT cadmium zinc telluride EKG electric signal from the heart FBP filtered backprojection FOV field-of-view GE General Electric Ge(Li) germanium detector doped with lithium MLEM maximum likelihood expectation maximization NaI(Tl) sodium iodine doped with thallium NM nuclear medicine OSEM ordered subset expectation maximization PET positron emiss...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 2003