Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial.
نویسندگان
چکیده
BACKGROUND Awareness is an uncommon complication of anaesthesia, affecting 0.1-0.2% of all surgical patients. Bispectral index (BIS) monitoring measures the depth of anaesthesia and facilitates anaesthetic titration. In this trial we determined whether BIS-guided anaesthesia reduced the incidence of awareness during surgery in adults. METHODS We did a prospective, randomised, double-blind, multicentre trial. Adult patients at high risk of awareness were randomly allocated to BIS-guided anaesthesia or routine care. Patients were assessed by a blinded observer for awareness at 2-6 h, 24-36 h, and 30 days after surgery. An independent committee, blinded to group identity, assessed every report of awareness. The primary outcome measure was confirmed awareness under anaesthesia at any time. FINDINGS Of 2463 eligible and consenting patients, 1225 were assigned to the BIS group and 1238 to the routine care group. There were two reports of awareness in the BIS-guided group and 11 reports in the routine care group (p=0.022). BIS-guided anaesthesia reduced the risk of awareness by 82% (95% CI 17-98%). INTERPRETATION BIS-guided anaesthesia reduces the risk of awareness in at-risk adult surgical patients undergoing relaxant general anaesthesia. With a cost of routine BIS monitoring at US16 dollars per use in Australia and a number needed to treat of 138, the cost of preventing one case of awareness in high-risk patients is about 2200 dollars.
منابع مشابه
Violence-related mortality in Iraq, 2002-2006.
n engl j med 359;4 www.nejm.org july 24, 2008 431 Pavlin JD, Souter KJ, Hong JY, Freund PR, Bowdle TA, Bower 1. JO. Effects of bispectral index monitoring on recovery from surgical anesthesia in 1,580 inpatients from an academic medical center. Anesthesiology 2005;102:566-73. Lindholm ML, Brudin L, Sandin RH. Bispectral index moni2. toring: appreciated but does not affect drug dosing and hypnot...
متن کاملProtocol for the "Michigan Awareness Control Study": A prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness
BACKGROUND The incidence of intraoperative awareness with explicit recall is 1-2/1000 cases in the United States. The Bispectral Index monitor is an electroencephalographic method of assessing anesthetic depth that has been shown in one prospective study to reduce the incidence of awareness in the high-risk population. In the B-Aware trial, the number needed to treat in order to prevent one cas...
متن کاملEffect of bispectral index monitoring on extubation time and analgesic consumption in abdominal surgery: a randomised clinical trial.
PRINCIPLES The aim of this study was to investigate the effect of bispectral index (BIS) monitoring on intra-operative anaesthesia consumption and extubation time. DESIGN Randomised controlled study. METHODS The study included 45 patients undergoing major abdominal surgery under general anaesthesia in a six month period (February - July 2011), aged 18 years or older, and classified as ASA (...
متن کاملCalculation of cerebral perfusion pressure in the management of traumatic brain injury: joint position statement by the councils of the Neuroanaesthesia and Critical Care Society of Great Britain and Ireland (NACCS) and the Society of British Neurological Surgeons (SBNS).
carbon dioxide partial pressure difference in early resuscitation fromseptic shock: A prospective observational study. Eur J Anaesthesiol 2014; 31: 361–80 11. Peake SL, Delaney A, Bailey M, et al. Goal-directed resuscitation for patients with early septic shock. N Engl J Med 2014; 371: 1496–506 12. Yealy DM, Kellum JA, Huang DT, et al. A randomized trial of protocol-based care for early septic ...
متن کاملWhy does bispectral index monitoring not perform better?
To the Editor: We read with great interest the results of the largest Bispectral Index (BIS) monitoring study ever performed, which was published in the October 2012 issue of Anesthesiology.1 No significant difference in intraoperative awareness with explicit recall was detected between BIS and anesthetic concentration protocols (0.08 vs. 0.12%, P = 0.48) in an unselected surgical population of...