Administered activity optimization in 99mTc-MAG3 renography for adults.

نویسندگان

  • Marlén P Díaz
  • Eric E Aparicio
  • Oscar D Rizo
  • Reinaldo R Díaz
  • Carlos H Rodríguez
چکیده

OBJECTIVE The objective of this work was to determine the minimum administered activity of (99m)Tc-mercaptoacetyltriglycine (MAG3) needed both to estimate effective renal plasma flow (ERPF) with adequate precision and to obtain good image quality. METHODS Three groups of 10 patients each were injected with 45, 71, or 132 MBq of MAG3. Renograms and perfusion and clearance images were obtained. The age, sex, and weight of the patients; the labeling yield; the mean count and counting rate 2 min after injection; the kidney-to-background and cortex-to-background ratios; the uptake time from the renograms; the percentage of the injected activity 2 min after injection in the left and right kidneys (A2(LK) and A2(RK), respectively); and the ERPF for both kidneys were obtained and analyzed. Discriminant analysis of image quality was used to select the variables that most affected image quality. The selected variables were studied among activity groups to optimize the amount of activity administered in these studies. RESULTS Precision in ERPF assessment did not significantly differ among administered activity levels (P = 0.824). The SDs of the ERPF were +/-1.5 for 132 MBq, +/-1.7 for 71 MBq, and +/-2.0 for 45 MBq. The labeling yield, the ratios of counts in the left and right kidneys to the background and in the left and right cortices to the background, and A2(LK) and A2(RK) were the only variables that provided a significant discriminant function for image quality. The only variable that significantly differed with the variation in administered activity was the ratio of counts in the right kidney to the background (P = 0.026), most likely because of the labeling yield. CONCLUSION A 45-MBq activity is sufficient to guarantee good image quality and adequate precision in ERPF determination from the time-activity curve, provided the labeling yield is kept high.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]

Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...

متن کامل

99mTc-MAG3: review of pharmacokinetics, clinical application to renal diseases and quantification of renal function.

About 14 years have passed since Fritzberg et al. developed 99mTc-MAG3 in 1986. The biological properties of this radiopharmaceutical are somewhat different from radioiodine labeled hippurate: it exhibits higher protein binding, slower blood clearance, higher extraction efficiency by tubular cells and larger excretion into the bile than the latter. Nonetheless, it has been widely used as the ag...

متن کامل

Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance

Objective(s): Renography is used for the diagnostic evaluation of pediatric patients with a suspected obstruction of urinary tract or impaired renal function. The recommended dose for children have been released by the European Association of Nuclear Medicine, Society of Nuclear Medicine and Molecular Imaging, and Japanese Society of Nuclear Medicine. Since acquisition counts in dynamic scintig...

متن کامل

F+0 diuresis renography in infants and children.

UNLABELLED The purpose of this study was to evaluate the feasibility of modifying diuresis renography by the simultaneous administration of 99mTc-mercaptoacetyltriglycine (MAG3) and furosemide in the investigation of hydronephrosis and hydroureteronephrosis in infants and children. Two parameters were assessed: the diuretic response in normal kidneys and the ability of the F+0 study to differen...

متن کامل

Synthesis, formulation and quality control of 99mTc-MAG3, as a renal tubular 99mTc-radiopharmaceutical kit [Persian]

Radionuclidic techniques may provide assessment of glomerular filtration rate (GFR) effective renal plasma flow (ERPF) or individual renal function. Several agents were available for determination of these parameters such as ¹³¹I-OIH (O-iodohippurate) and different derivatives of DADS (Diamidodisulfur). OIH has the disadvantage of imparting a relatively high absorbed radiation dose to the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2003