Direct determination of serum chloride with a semiautomated discrete analyzer.

نویسنده

  • S S Levinson
چکیده

I show how mercuric thiocyanate reagent can be used in assaying serum chloride economically, rapidly, and precisely. I used a semiautomated discrete analyzer with direct concentration read-out capability but the method can easily be applied to many mechanized instruments. Linearity between concentration and color is obtained by adding appropriate amounts of mercuric nitrate to the reagent. As many as 300 samples can be assayed per hour, and the method is excellent for emergency use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semiautomated homogeneous enzyme immunoassay of total serum thyroxine with a kinetic analyzer.

A new semiautomatic procedure for determination of total serum thyroxine was adapted to a kinetic analyzer, LKB 2086 Mark II. The ABA thyroxine assay kit was used, and although the assay procedure was modified, the advantage of small reagent volumes, short measuring times, and automation were retained. The results were analyzed off-line with a programmable desk-top calculator. The method has a ...

متن کامل

Calculation of plasma chloride levels using blood gas measurements

Objective: Chloride is the major plasma anion. There are several methods available for the determination of serum chloride levels. Unfortunately these methods are sometimes not available in the urgent setting where values are needed. Here we describe...

متن کامل

An evaluation of the Beckman chloride/carbon dioxide analyzer.

We compared the Beckman Cl/CO2 Analyzer to the American Instrument Company chloride titrator for measurement of chloride in serum, sweat, and spinal fluid. We also compared it to the Natelson gasometer and a modified continuous-flow (AutoAnalyzer) technique for measurement of carbon dioxide in serum. Effects of bilirubin and hemoglobin on results for both the CO2, and Cl were negligible. The li...

متن کامل

Molecular Interaction of Benzalkonium Ibuprofenate and its Discrete Ingredients with Human Serum Albumin

Studying the interaction of pharmaceutical ionic liquids with human serum albumin (HSA) can help investigating whether or not ionic liquid formation can enhance pharmacological profile of the discrete ingredients. In this respect, in the present work, the interactions of Benzalkonium Ibuprofenate, as a well-known active pharmaceutical ionic liquid, Benzalkonium Chloride, and also Sodium Ibuprof...

متن کامل

Modification of Lofland's colorimetric semiautomated serum triglyceride determination, assessed by an enzymatic glycerol determination.

Erroneously high values for serum triglyceride levels obtained with the semiautomated method of Lofland were found to be due to contamination of the isopropanol extracts with glucose or other carbohydrate. Treatment of the isopropanol extracts with a mixture of copper sulfate and calcium hydroxide removed the contaminating glucose. Analysis of the glucose-free extracts by either the semiautomat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1976