BACKGROUND Several methods that are currently used for contouring analysis have problems providing reliable and/or meaningful results. In this paper a solution to these problems is proposed in a form of a novel measure, which was developed based on requirements defined for contouring studies. MATERIALS AND METHODS The proposed distance deviation measure can be understood as an extension of the closest point measures in such a way that it does not measure only distances between points on contours but rather analyse deviation of distances to both/all contours from each image point/voxel. The obtained result is information rich, reliable and provided in a form of an image, enabling detailed topographic analysis. In addition to image representation, results can be further processed into angular representation for compact topographic analysis or into overall scalar estimates for quick assessment of contour disagreement. RESULTS Distance deviation method is demonstrated on a multi observer contouring example with complex contour shapes, i.e., with pronounced extremes and void interior. The results are presented using the three proposed methods. CONCLUSIONS The proposed method can detect and measure contour variation irrespective of contour complexity and number of contour segments, while the obtained results are easy to interpret. It can be used in various situations, regarding the presence of reference contour or multiple test contours.
منابع مشابه
Investigation of variability in image acquisition and contouring during 3D ultrasound guidance for partial breast irradiation
BACKGROUND Three-dimensional ultrasound (3DUS) at simulation compared to 3DUS at treatment is an image guidance option for partial breast irradiation (PBI). This study assessed if user dependence in acquiring and contouring 3DUS (operator variability) contributed to variation in seroma shifts calculated for breast IGRT. METHODS Eligible patients met breast criteria for current randomized PBI ...
متن کاملQuantification of infarct size and myocardium at risk: evaluation of different techniques and its implications
AIMS The aim of this study was to evaluate seven methods for quantifying myocardial oedema [2 standard deviation (SD), 3 SD, 5 SD, full width at half maximum (FWHM), Otsu method, manual thresholding, and manual contouring] from T2-weighted short tau inversion recovery (T2w STIR) and also to reassess these same seven methods for quantifying acute infarct size following ST-segment myocardial infa...
متن کاملComparison of 3D MRI with high sampling efficiency and 2D multiplanar MRI for contouring in cervix cancer brachytherapy
BACKGROUND MRI sequences with short scanning times may improve accessibility of image guided adaptive brachytherapy (IGABT) of cervix cancer. We assessed the value of 3D MRI for contouring by comparing it to 2D multi-planar MRI. PATIENTS AND METHODS In 14 patients, 2D and 3D pelvic MRI were obtained at IGABT. High risk clinical target volume (HR CTV) was delineated by 2 experienced radiation ...
متن کاملAn evaluation of the robustness of organ-at-risk recommendations made by GEC/ESTRO according to interobserver variability: a single-center experience
PURPOSE Groupe Européen de Curiethérapie (GEC) and European Society for Radiotherapy & Oncology (ESTRO) has proposed a rectal dose constraint of the most exposed 2-cc volume (D2cc of ≤ 75 Gy EQD2α/β = 3) during external-beam plus high-dose-rate brachytherapy (HDR-BT) in localized prostate cancer patients. This study aimed to evaluate D2cc for rectal contouring via interobserver variability. M...
متن کاملModeling and Control of Contouring Errors for Five-Axis Machine Tools—Part I: Modeling
Aerospace, die, and mold industries utilize parts with sculptured surfaces, which are machined on five-axis computer numerical controlled machine tools. Accurate path tracking for contouring is not always possible along the desired space curves due to the loss of joint coordination during the five-axis motion. This two-part paper presents modeling and robust control of contouring errors for fiv...