Internal jugular catheter malposition in a patient with end stage renal disease: a case report.

نویسندگان

  • Farzaneh Ebrahimifard
  • Amir Shirvani
  • Shahab Abtahi
  • Ali Setayesh
چکیده

A 30-year-old female with end-stage renal disease was a candidate for dual lumen catheter placement. After catheter insertion, O2 saturation measurement of the aspirated blood from the catheter was similar to that of arterial blood. They referred the patient to our hospital after 48 hours. Diagnostic procedures revealed that the tip of the catheter had entered the pleural cavity. Catheter removal in the CPR room resulted in hemorrhagic shock. The patient was resuscitated and stabilized and sent to the operating room. A laceration found at the junction of right jugular and right subclavian veins and was surgically repaired. The patient was discharged after ten days without any complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A catheter malpositioned patient with pain and paresthesia

We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...

متن کامل

Malposition of central venous catheter in the left internal jugular vein--a case report.

Malposition of central venous catheter is a complication of central venous catheterization. A case of left internal jugular catheterization via left external jugular vein is reported. Details of the procedure are described and the literature is reviewed for similar malpositions.

متن کامل

Sonographic diagnosis of catheter malposition in a patient with postoperative plexus lesion after right internal jugular vein catheterization--case report.

PURPOSE Postoperative brachial plexus lesion has been reported only rarely after catheterization of the right internal jugular vein (RIJV), and then is usually considered to be the result of puncture hematoma. CLINICAL FEATURES We here present the case of plexus brachialis injury after catheterization of the RIJV with ultrasonography showing direct compression of the plexus brachialis by a ce...

متن کامل

Early dysfunction of transplanted kidney revealed the cause of recurrent nephrolithiasis: a case report of primary hyperoxaluria

Primary hyperoxaluria (PH) disorder causes end-stage renal disease (ESRD). Missed diagnosis or relapse in transplanted kidney is common. We present a 36-year-old patient with a history of recurrent renal calculus which progressed to end-stage renal disease. He underwent kidney-transplant surgery. Renal function tests had worsening progressively at first-week post-transplant. Transplanted kidney...

متن کامل

Report of a Case of Immunoglobulin A Nephropathy in a Patient Without a Family History of Kidney Disease

Introduction: IgA Nephropathy is the most common form of glomerulonephritis and the major cause of end-stage renal disease. Gross or microscopic hematuria is a common symptom of hematuria and occurs in less than 5% to 10% of patients with IGM with rapidly progressive glomerulonephritis. The aim of this study was to investigate the diagnostic biomarkers of this disease after biopsy. Methods: IgA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica Iranica

دوره 52 9  شماره 

صفحات  -

تاریخ انتشار 2014