Effect of ventilator circuit changes on ventilator-associated pneumonia: a systematic review and meta-analysis.

نویسندگان

  • Jiangna Han
  • Yaping Liu
چکیده

BACKGROUND Recent guidelines concerning prevention of ventilator-associated pneumonia recommend that ventilator circuits should not be changed routinely, but in practice circuit changes at regular intervals persist. METHODS We searched the MEDLINE, EMBASE, and SCOPUS databases and reviewed citations to identify articles that reported the results of randomized controlled trials and sequential comparison studies that provided a clearly defined intervention of circuit changes (interval > or = 2 d) and the outcome measure of the development of ventilator-associated pneumonia in mechanically ventilated adult patients. Both authors independently assessed the validity of the included studies, and extracted data using a pre-designed data-collection form. We used a random-effect model to combine data from studies that compared circuit changes every 2 days versus every 7 days, and circuit changes at regular intervals versus no routine circuit change. RESULTS The search yielded 10 reports, which included 19,169 patients. Compared to patients exposed to circuit changes every 7 days, patients who received circuit changes every 2 days had a higher risk of ventilator-associated pneumonia (odds ratio 1.928, 95% confidence interval 1.080-3.443). Compared to no routine circuit change, changing the ventilator circuit at a 2-day or 7-day interval was associated with an odds ratio of 1.126 (95% confidence interval 0.793-1.599). There was a trend of reduced risk of pneumonia as circuit-change intervals were extended. CONCLUSIONS Frequent ventilator circuit changes are associated with a high risk of ventilator-associated pneumonia. No routine circuit change is safe and justified. Hospital infection-control policies and bedside practitioners should translate the evidence into clinical practice, if they haven't done so already.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Effect of Using Normal Saline and Distilled Water for Tracheal Suctioning on the Incidence of Ventilator-associated Pneumonia and Hemodynamic Indexes in Ventilator-dependent Patients

Background and Aims: VAP prevention is a top priority in the intensive care units. The study was conducted to compare the effect of using normal saline and distilled water for tracheal suctioning on the incidence of ventilator-associated pneumonia and hemodynamic indexes in ventilator-dependent patients. Methods: The present study is a randomized clinical trial that was conducted from 2017 to 2...

متن کامل

Subglottic secretion drainage for the prevention of ventilator-associated pneumonia: a systematic review and meta-analysis.

BACKGROUND AND PURPOSE Aspiration of secretions containing bacterial pathogens into the lower respiratory tract is the main cause of ventilator-associated pneumonia. Endotracheal tubes with subglottic secretion drainage can potentially reduce this and, therefore, the incidence of ventilator-associated pneumonia. New evidence on subglottic secretion drainage as a preventive measure for ventilato...

متن کامل

Nurses’ knowledge of evidence- based guidelines for preventing ventilator-associated pneumonia in intensive care units

Background and Purpose: Implementing the guidelines to prevent VAP has been shown to have a significant effect on reducing the incidence of VAP. Studies indicate that ICU staff have poor knowledge and low implementation rate of the standard preventive measures related to VAP. The present study aims to evaluate the knowledge of nurses in the intensive care unit in University hospitals of Sari. ...

متن کامل

Strategies for the Prevention of Ventilator-associated Pneumonia in the Intensive Care Units: A Review

Ventilator-Associated Pneumonia (VAP) accounts for 80%-90% of hospital-acquired pneumonia cases in Intensive Care Units (ICUs). VAP occurs 48-72 hours after intubation, and is observed in 27%-29% of patients with endotracheal tube, and its risk increases with the increase in the duration of mechanical ventilation. In this review study, papers published from 1996-2018 were used to investigate st...

متن کامل

Oral decontamination for prevention of pneumonia in mechanically ventilated adults: systematic review and meta-analysis.

OBJECTIVE To evaluate the effect of oral decontamination on the incidence of ventilator associated pneumonia and mortality in mechanically ventilated adults. DESIGN Systematic review and meta-analysis. DATA SOURCES Medline, Embase, CINAHL, the Cochrane Library, trials registers, reference lists, conference proceedings, and investigators in the specialty. REVIEW METHODS Two independent rev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2010