Development of a Calibration Methodology of the Patient Dose Calibrator
نویسندگان
چکیده
The kerma-area product (PKA) is a useful quantity to establish the reference levels in diagnosis of conventional X ray examinations. A KAP meter can be calibrated in laboratory or in situ, where it is used. The patient dose calibrator (PDC) is a new equipment from Radcal that measures PKA. It was manufactured following the IEC 60580 recommendations. The aim of this study was to calibrate the PDC in order to use it as a standard device for calibration of KAP meters. The materials used were: a radiation system, the PDC, a monitor ionization chamber and an RC6 ionization chamber. The monitor ionization chamber was calibrated against the RC6 secondary standard ionization chamber. After that, the PDC was calibrated using the monitor ionization chamber as reference. The calibration of the PDC in radiation standard beams allows the determination of a special procedure to calibrate the KAP meter. Its behaviour demonstrates low energy dependence and it can be used as a reference instrument to calibrate clinical KAP meters.
منابع مشابه
A Recommendation for Revised Dose Calibrator Measurement Procedures for 89Zr and 124I
Because of their chemical properties and multiday half lives, iodine-124 and zirconium-89 are being used in a growing number of PET imaging studies. Some aspects of their quantitation, however, still need attention. For (89)Zr the PET images should, in principle, be as quantitatively accurate as similarly reconstructed 18F measurements. We found, however, that images of a 20 cm well calibration...
متن کاملکنترل کیفی و کالیبراسیون دستگاه های دزکالیبراتور RAMS-88 در مراکز پزشکی هسته ای ایران
The aim of this paper is the examining ways for quality control and calibration of Rams-88 calibrator. The device measures the amount of &gamma and &beta rays in radio medicines by means of the amount of radioactivity of radio nuclide. In this paper experiments has been done for explaining correct operation of these devices using standard method including precision, accuracy and linearit...
متن کاملMulticentre harmonization of 89Zr PET/CT performance
This study investigated the feasibility of quantitative accuracy and harmonized image quality in Zr-PET/CT multicentre studies. Methods: Five PET/CT scanners from 3 vendors were included. Zr activity was measured in a central dose calibrator before delivery.Local activity assays were based on volume as well as on the local dose calibrator. Accuracy and image noise were determined from a cross c...
متن کاملMulticenter harmonization of 89Zr PET/CT performance.
UNLABELLED This study investigated the feasibility of quantitative accuracy and harmonized image quality in (89)Zr-PET/CT multicenter studies. METHODS Five PET/CT scanners from 3 vendors were included. (89)Zr activity was measured in a central dose calibrator before delivery. Local activity assays were based on volume as well as on the local dose calibrator. Accuracy and image noise were dete...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کامل