Characterization of a hERG screen using the IonWorks HT: comparison to a hERG rubidium efflux screen.
نویسندگان
چکیده
The introduction of parallel patch clamp instruments offers the promise of moderate-throughput, high-fidelity voltage clamp for drug screening assays. One such device, the IonWorks HT (Molecular Devices, Sunnyvale, CA), was evaluated and compared to conventional human ethera- go-go-related gene (hERG) patch clamp data and an alternative functional screen based on rubidium flux. Data generated by the IonWorks HT and rubidium assays were compared to determine if either offered superior predictive value compared to conventional patch clamp. Concentration-effect curves for a panel of known hERG blockers were shifted to higher concentrations on the IonWorks HT compared to conventional voltage clamp determinations. The magnitude of the potency shifts was compound-specific and ranged from no shift (e.g., quinidine) to over 200-fold (astemizole). When the extreme value for astemizole was disregarded, the potency shift for 13 other known reference standards was 12-fold or less, with an average shift of fivefold. The same subset of compounds in the rubidium efflux assay exhibited an average potency shift of 12-fold. To provide a simulation of how the IonWorks HT assay might perform in a single concentration screening mode, a panel of test compounds was evaluated. The IonWorks HT screen did not outperform the rubidium efflux screen in predicting conventional voltage clamp measurements. The most likely explanation appears to rest with variable and compound-specific potency shifts in the IonWorks HT assay. The variable potency shifts make it difficult to select a screening concentration that meets the criterion of a high positive predictive value while avoiding false-positives.
منابع مشابه
Evaluation of the rubidium efflux assay for preclinical identification of HERG blockade.
Inhibition of the delayed-rectifier potassium channel current, human ether-a-go-go (hERG), by pharmaceutical agents can lead to acquired long QT syndrome and the generation of potentially lethal arrhythmias and sudden death. There remains an unmet need for higher-throughput assays to screen compounds in preclinical development for the potential to block hERG and cause QT prolongation. We evalua...
متن کاملA place for high-throughput electrophysiology in cardiac safety: screening hERG cell lines and novel compounds with the ion works HTTM system.
Several commercially available pharmaceutical compounds have been shown to block the IKr current of the cardiac action potential. This effect can cause a prolongation of the electrocardiogram QT interval and a delay in ventricular repolarization. The Food and Drug Administration recommends that all new potential drug candidates be assessed for IKr block to avoid a potentially lethal cardiac arr...
متن کاملPrediction of Thorough QT study results using action potential simulations based on ion channel screens
INTRODUCTION Detection of drug-induced pro-arrhythmic risk is a primary concern for pharmaceutical companies and regulators. Increased risk is linked to prolongation of the QT interval on the body surface ECG. Recent studies have shown that multiple ion channel interactions can be required to predict changes in ventricular repolarisation and therefore QT intervals. In this study we attempt to p...
متن کاملIn silico classification of HERG channel blockers: a knowledge-based strategy.
The blockage of the hERG potassium channel by a wide number of diverse compounds has become a major pharmacological safety concern as it can lead to sudden cardiac death. In silico models can be potent tools to screen out potential hERG blockers as early as possible during the drug-discovery process. In this study, predictive models developed using the recursive partitioning method and created ...
متن کاملDrugs, hERG and sudden death.
Early recognition of potential QT/TdP liability is now an essential component of the drug discovery/drug development program. The hERG assay is an indispensable step and a high-quality assay must accompany any investigational new drug (IND) application. While it is the gold standard at present, the hERG assay is too labor-intensive and too low throughput to be used as a screen early in the disc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Assay and drug development technologies
دوره 3 1 شماره
صفحات -
تاریخ انتشار 2005