Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology.

نویسندگان

  • Dustin R Bunch
  • Abby Y Miller
  • Sihe Wang
چکیده

BACKGROUND Vitamin D is important to health and disease. Liquid chromatography-tandem mass spectrometry (LC-MSMS) is considered the most accurate technology for quantification of serum 25-hydroxyvitamin D (25OHD) which is the best biomarker for estimating vitamin D nutritional status. METHODS Serum was mixed with acetonitrile containing hexadeuterated 25-hydroxyvitamin D(3) (d(6)-25OHD3) and centrifuged 10 min at 15,634Xg. The supernatant was injected onto a turbulent flow preparatory column then transferred to a polar endcapped C18 analytical column. The mass spectrometer was set for positive atmospheric pressure chemical ionization. RESULTS The analytical cycle time was 5.5 min. Inter- and intra-assay CV for both analytes across three concentrations ranged from 3.8% to 14.2%. The method was linear from 3.0 to 283.6 nmol/L for 25-hydroxyvitamin D(3) (25OHD3) and 4.6 to 277.9 nmol/L for 25-hydroxyvitamin D(2) (25OHD2), with an accuracy of 88.7%-118.7% and 90.7%-100.3%, respectively. No carryover or ion suppression was observed. Comparison with a radioimmunoassay using patient specimens (n=527) showed a mean difference of 5.2%, and diagnostic agreement of 80.9% with Deming regression of slope 0.867, intercept 12.8, standard error of estimate (SEE) 17.4, and r=0.8425. CONCLUSIONS The LC-MSMS method coupled with turbulent flow technology for serum 25OHD quantitation is rapid, efficient, and suitable for clinical testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry.

BACKGROUND 25-hydroxyvitamin D [25(OH)D] assays are characterized by poor between-assay comparability. This result emphasizes the need for reference measurement procedures (RMPs) to establish calibration traceability and assist in method validation. We aimed at developing candidate RMPs on the basis of isotope- dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) for separate q...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

HPLC method for 25-hydroxyvitamin D measurement: comparison with contemporary assays.

BACKGROUND The concentration of 25-hydroxyvitamin D [25(OH)D] in serum has been designated the functional indicator of vitamin D (VitD) nutritional status. Unfortunately, variability among 25(OH)D assays limits clinician ability to monitor VitD status, supplementation, and toxicity. METHODS We developed an HPLC method that selectively measures 25-hydroxyvitamin D2 [25(OH)D2] and D3 [25(OH)D3]...

متن کامل

SPE and LC-MS/MS Method for the Determination of 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 from Human Plasma

A liquid chromatography tandem mass spectrometry method for 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 from human plasma has been developed. Sample preparation was fast and efficient using a Thermo ScientificTM SOLATM hydrophobic reversed phase (HRP) plate. Analysis was carried out using a Thermo ScientificTM SyncronisTM C18 1.7 μm, 50 × 2.1 mm column to give a fast separation with a cycle t...

متن کامل

Performance evaluation of two immunoassays for 25-hydroxyvitamin D

Although immunoassays in measuring 25-hydroxyvitamin D [25(OH)D] have been improved recently, relatively large differences are still seen between results of 25(OH)D measured by immunoassays and by liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the present studies, we compared two immunoassays with LC-MS/MS for measuring 25(OH)D concentrations. Concentrations of 25-hydroxyvitamin ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 2009