AbstractID: 7461 Title: Multileaf Collimator (MLC) for Field Matching
ثبت نشده
چکیده
ID: 7461 Title: Multileaf Collimator (MLC) for Field Matching Photon field matching at the beam isocenter using independent jaws is the method of choice in many radiation treatments that require abutted fields. This study evaluated the suitability of using Multileaf Collimator (MLC) for such matching. The study employed a treatment planning system to model the field matching and the modeling was verified using x-ray film dosimetry. In this study, it was found that, for a double focused MLC system the MLC profile characteristics, especially the characteristics at the penumbra regions, were essentially the same as that of independent jaws. As such double focused MLC beam matching closely resembled that of independent jaws. In addition, it was found that the dose change varied linearly with the gap overlap (from 3 mm gap to 3 mm overlap) with a coefficient of 12 ± 2 %/mm. Using an auto field-sequencing machine operation the junction could be offset once or twice by ± 1 cm within an irradiation. Such intra-fraction ‘feathering’ of junction resulted in a reduction of the slope of the curve (from 12 ± 2 %/mm to 6 ± 2 %/mm when the junction was moved once and to 4 ± 2 %/mm when moved twice). A major difference between independent and MLC jaw field matching was that the former resulted in a uniform match line but the latter a line of underdoses/overdoses depending on the formation of gaps/overlaps by individual leaf pairs. Thus the intra-fraction ‘feathering’ would be the key to a successful application of MLC for isocentric field matching.
منابع مشابه
Physical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D
Background:Â Before treatment planning and dose delivery, quality assurance of multi-leaf collimator (MLC) has an important role in intensity-modulated radiation therapy (IMRT) due to the creation of multiple segments from optimization process.Objective: The purpose of this study is to assess the quality control of MLC leaves using EBT3 Gafchromic films.Material and Methods: Leaf Position accur...
متن کاملThe Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions
Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...
متن کاملDesign and Fabrication of the Mechanical Part of a Prototype Multileaf Collimator System
Introduction: Multileaf collimator (MLC) is state of the art among the radiation field shaping systems for conformal radiotherapy techniques. Some advantages of this system are as follow: reduction of treatment time, higher precision in conforming the radiation field to the projection of the target volume and lowering the chance of errors made by technologists. The purpose of this research was ...
متن کاملBeam characteristic of P.E collimators Add-on multileaf collimator
Introduction: Multileaf collimators (MLCs) are computer-controlled devices which are Useful and cost-effective tools for conformal therapy and intensity modulation radiotherapy (IMRT). Nowadays MLCs are important and standard configuration of the new medical linear accelerators which are substitute of conventional Blocks and has eliminated the ...
متن کاملUse of a multileaf collimator to increase the field width achievable with a dynamic wedge
A method is proposed for generating dynamic wedges spanning the entire field width, defined as the collimator opening in the wedged direction, without changes to existing hardware. The technique approximates the fluence pattern of a dynamic wedge by sequentially closing the leaves of a 120-leaf multileaf collimator (MLC). Closure times for the individual leaves were derived by extending the seg...
متن کامل