A backprojection filtering algorithm for a spatially varying focal length collimator

نویسندگان

  • Gengsheng Lawrence Zeng
  • Grant T. Gullberg
چکیده

Fan-beam collimators are used in single photon emission computed tomography to improve the sensitivity for imaging of small organs. The disadvantage of fan-beam collimation is the truncation of projection data surrounding the organ of interest or, in those cases of imaging large patients, of the organ itself producing reconstruction artifacts. A spatially varying focal length fan-beam collimator has been proposed to eliminate the truncation problem and to maintain good sensitivity for the organ of interest. The collimator is constricted so that the focal lengths of the holes vary across the face of the collimator with the shortest focal lengths at the center and the longer focal lengths at the periphery of the collimator. The variation of the focal length can have various functional forms but in the authors' work it is assumed to increase monotonically toward the edge of the collimator. A backprojection filtering reconstruction algorithm is derived for this type of collimation. The algorithm first backprojects the projections, then performs a two-dimensional filtering. The algorithm is efficient and has been tested via computer simulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam projections.

In single photon emission computed tomography (SPECT), a varying-focal-length cone-beam collimator can be used to reduce the truncation problem and to maintain sensitivity when imaging the organ of interest. The collimator is constructed so that the collimator holes focus to a circular symmetric, spatially varying, focal point function. The focal length increases radially from the shortest foca...

متن کامل

Fan-beam reconstruction algorithm for a spatially varying focal length collimator

Fan-beam collimators are used in single-photon-emission computed tomography (SPECT) to improve the sensitivity for imaging of small organs. The disadvantage of fan-beam collimation is the truncation of projection data surrounding the organ of interest or, in those cases of imaging large patients, of the organ itself, producing reconstruction artifacts. A spatially varying focal length fan-beam ...

متن کامل

Analytical Compensation for Spatially Variant Detector Response in SPECT With Varying Focal-Length Fan-Beam Collimators

The authors present a new method to compensate for the spatially variant detector response in single photon emission computed tomography (SPECT) with varying focal-length fan-beam (VFF) geometry. In this method, the deblurred projection is explicitly expressed as an integral of the collimator blurred data and the fully calibrated system kernel matrix with certain transforms. It needs a little m...

متن کامل

Backprojection Filtering for Variable Orbit Fan-beam Tomography

Backprojection filtering algorithms are presented for three variable orbit fan-beam geometries. Expressions for the fanbeam projection and backprojection operators are given for a flat detector fan-beam geometry with fixed focal length, with variable focal length, and with fixed focal length and off-center focusing. Backprojection operators are derived for each geometry using transformation of ...

متن کامل

An inversion formula for the exponential radon transform in spatial domain with variable focal-length fan-beam collimation geometry.

Inverting the exponential Radon transform has a potential use for SPECT (single photon emission computed tomography) imaging in cases where a uniform attenuation can be approximated, such as in brain and abdominal imaging. Tretiak and Metz derived in the frequency domain an explicit inversion formula for the exponential Radon transform in two dimensions for parallel-beam collimator geometry. Pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on medical imaging

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 1994