The continuous recording of central venous pressure changes from an arm vein.
نویسندگان
چکیده
With the subject in the right lateral decubitus position, changes of central venous pressure can be recorded accurately and conveniently from a vein in the antecubital fossa of the dependent arm. Theoretically the hydrostatic pressure transforms the venous bed between the heart and the site of puncture into uninterrupted wide channels with relatively low distensibility. Simultaneous recordings of pressure by the method described and by catheterization of the central veins showed that induced changes of central venous pressure were identically recorded from both sites. The mean pressure gradient between the peripheral and central veins was 35 mm. of water.
منابع مشابه
A venous outflow method for measurement of rapid changes of the cerebral blood flow and oxygen consumption in the rat.
A technique for continuous measurement of cerebral venous outflow in the rat is described. The method involves cannulation of one retroglenoid vein close to its exit from the skull, and diversion of cerebral venous blood through a closed extracorporal circuit with a drop recording device, the blood being returned to the central venous circulation via a catheter in the external jugular vein. Occ...
متن کاملThe efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation
Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...
متن کاملCorrelation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock
Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...
متن کاملDetermination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کاملNew observations concerning the nature of central retinal vein pulsation.
AIMS Central retinal vein pulsation is affected by intracranial pressure (ICP), glaucoma and venous pathology. Its genesis is poorly understood with most models suggesting that intraocular pressure (IOP) fluctuation dominates the rhythm of venous pulsation; however, this has not been explored experimentally. This study planned to measure the timing of central retinal vein pulsation with respect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 4 1 شماره
صفحات -
تاریخ انتشار 1956