Intraocular lenses in children: changes in axial length, corneal curvature, and refraction.

نویسندگان

  • D I Flitcroft
  • D Knight-Nanan
  • R Bowell
  • B Lanigan
  • M O'Keefe
چکیده

AIM To assess changes in axial length, corneal curvature, and refraction in paediatric pseudophakia. METHODS 35 eyes of 24 patients with congenital or developmental lens opacities underwent extracapsular cataract extraction and posterior chamber intraocular lens implantation. Serial measurements were made of axial length, corneal curvature, objective refraction, and visual acuity. RESULTS For patients with congenital cataracts (onset < 1 year age) the mean age at surgery was 24 weeks. Over the mean follow up period of 2.7 years, the mean increase in axial length of 3.41 mm was not significantly different from the value of an expected mean growth of 3.44 mm (paired t test, p = 0.97) after correction for gestational age. In the developmental cataract group (onset > 1 year of age) the mean age at surgery was 6.4 years with a mean follow up of 2.86 years. This group showed a mean growth in axial length of 0.36 mm that was not significantly different from an expected value of 0.47 mm (paired t test, p = 0.63). The mean preoperative keratometry was 47.78 D in the congenital group and 44.35 D in the developmental group. At final follow up the mean keratometry in the congenital group was 46.15 D and in the developmental group it was 43.63 D. In eyes followed for at least 2 years, there was an observed myopic shift by 24 months postoperatively of 3.26 D in the congenital cases (n = 10) and 0.96 D in the developmental cases (n = 18). CONCLUSION The pattern of axial elongation and corneal flattening was similar in the congenital and developmental groups to that observed in normal eyes. No significant retardation or acceleration of axial growth was found in the eyes implanted with IOLs compared with normal eyes. A myopic shift was seen particularly in eyes operated on at 4-8 weeks of age and it is recommended that these eyes are made 6 D hypermetropic initially with the residual refractive error being corrected with spectacles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Central corneal thickness of Iraqi population in relation to age, gender, refractive errors, and corneal curvature: a hospital-based cross-sectional study

BACKGROUND Central corneal thickness (CCT) is an important indicator of corneal status. Its measurement provides valid information about corneal physiological condition and possible changes associated with diseases, traumas, and hypoxia. It is an integral part for interpretation of intraocular pressure and glaucoma patient management and in prerefractive procedure assessment. OBJECTIVE The ai...

متن کامل

Part A: Biometry and Intraocular Lens Power Calculation

Formulas For Intraocular lens Power calculatIon Modern cataract surgery replaces the natural lens of the eye with an intraocular lens (IOL). After surgery, the optical system of the eye will consist of two major refractive elements, the cornea and the newly inserted IOL. This two-lens system is at the basis of IOL power calculation. To facilitate calculations, both the cornea and the IOL are co...

متن کامل

Myopia control with orthokeratology contact lenses in Spain: refractive and biometric changes.

PURPOSE To compare axial length growth between white children with myopia wearing orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) over a 2-year period. METHODS Subjects 6 to 12 years of age with myopia -0.75 to -4.00 diopters of sphere (DS) and astigmatism ≤1.00 diopters of cylinder (DC) were prospectively allocated OK or SV correction. Measurements of axial len...

متن کامل

Corneal Thickness Profile and Associations in Chinese Children Aged 7 to 15 Years Old

Corneal thickness (CT) maps of the central (2-mm diameter), para-central (2 to 5-mm diameter), peripheral (5 to 6-mm diameter), and minimum (5-mm diameter) cornea were measured in normal Chinese school children aged 7 to 15 years old using Fourier-domain optical coherence tomography. Multiple regression analyses were performed to explore the effect of associated factors [age, gender, refraction...

متن کامل

Corneal Biomechanics Determination in Healthy Myopic Subjects

Purpose. To determine the corneal biomechanical properties by using the Ocular Response Analyzer™ and to investigate potential factors associated with the corneal biomechanics in healthy myopic subjects. Methods. 135 eyes from 135 healthy myopic subjects were included in this cross-sectional observational study. Cornea hysteresis (CH), corneal resistance factor (CRF), cornea-compensated intraoc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 83 3  شماره 

صفحات  -

تاریخ انتشار 1999