Fetal radiation doses and subsequent risks from X-ray examinations: Should we be concerned?
نویسندگان
چکیده
BACKGROUND Pregnant women are sometimes exposed to ionizing radiation in radiology examinations for various reasons. In such cases, the radiation dose to the conceptus and subsequent risks should be estimated. OBJECTIVE The purpose of this study was the calculation and presentation of fetal dose and subsequent risks resulted from different X-ray examinations. MATERIALS AND METHODS An analytical simulation study was conducted and six common radiographies in different views and three types of special examinations were evaluated. The entrance skin exposure (ESE) was measured using a solid-state dosimeter. A Monte Carlo program was used in order to simulate different views of X-ray examinations and calculate the radiation doses received by the conceptus for every view of each examination. Then the risk of childhood cancer and small head size were calculated for different radiographies. RESULTS The fetal doses and consequence risks of the small head size and childhood cancer for the radiographs of chest, skull, and sinuses were negligible but the risks of childhood cancer and small head size due to radiographies of abdomen, lumbar spine, and pelvis areas were ponderable. CONCLUSION RESULTS of this study can be used for the pregnant women radiographies management.
منابع مشابه
Excess Cancer Risk Assessment from Some Common X-Ray Examinations in Sabzevar County
Introduction: Nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. Using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. X-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. These effects obey the LNT hypothesis that occur at lo...
متن کاملEvaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran
Introduction The purpose of this study was to estimate organ and effective doses in patients undergoing some common X-ray examinations in Sabzevar, Iran. The effective dose is one of the best parameters for describing the amount of radiation dose received by a patient undergoing any diagnostic X-ray examination. The public dose from X-ray examinations depends on various factors, and its contrib...
متن کاملAssessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria
Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs) in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State,...
متن کاملRadiological protection for diagnostic examination of pregnant women.
Application of diagnostic X-ray examination to pregnant women is complicated since risks to both mother and embryo/fetus must be considered. Embryos and fetuses are more sensitive to radiation than adults or children. The threshold doses for fetal death, malformations and mental retardation which are deterministic effects, are reported to be 100-200 mGy or higher. The relative risk for childhoo...
متن کاملOrgan and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)
ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...
متن کامل