Intraocular silicone oil: in vitro and in vivo MR and CT characteristics.

نویسندگان

  • V P Mathews
  • A D Elster
  • P B Barker
  • B L Buff
  • J A Haller
  • C M Greven
چکیده

PURPOSE To describe the CT and MR characteristics of intraocular silicone oil (polydimethylsiloxane), which is used with increasing frequency to treat complicated retinal detachments. METHODS CT was performed on a silicone oil/water phantom and on a patient with retinal detachments secondary to cytomegalovirus retinitis, treated by bilateral intraocular injections of silicone oil. CT appearance and CT number of silicone oil were evaluated. Proton MR spectroscopy was performed with a 200-MHz spectrometer on a sample of polydimethylsiloxane within a tube of deuterated water. MR imaging was performed on a silicone oil/water phantom and on two patients with retinal detachments treated with silicone oil injection. RESULTS Silicone oil is relatively radiodense; its CT attenuation is approximately 130 HU. On spectroscopy, silicone oil gave a single peak at 0.33 ppm. Relative to water silicone oil was hyperintense on T1-weighted images and hypointense on spin-density and T2-weighted images. Estimated T1 and T2 were 716 msec and 68 msec, respectively. Chemical shift artifacts were seen on MR images and were exaggerated when a narrow sampling bandwidth was used. In clinical cases spectral saturation pulses normally used for lipid suppression could be adjusted to saturate only the silicone resonance; in this way, the chemical shift artifact was eliminated. CONCLUSION Intraocular silicone oil has unique imaging characteristics with which radiologists must become familiar. These characteristics include high attenuation on CT and hyperintensity on T1-weighted MR, both of which may mimic hemorrhage. Elimination of the prominent chemical shift artifact on MR with selective saturation of the silicone resonance improves evaluation of the globe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal imaging protocol after intraocular silicone oil tamponade.

PURPOSE Our purpose was to define the optimal protocol for imaging of the orbits after vitreous humor replacement with silicone oil. METHODS Eleven eyes in 10 patients with tractional and/or rhegmatogenous retinal detachment were studied. Five CT scans and 18 high-field (1.5 T) MR images were obtained. Standard T1-weighted, T1-weighted with fat and silicone saturation, fast spin density-weigh...

متن کامل

Distribution of Triamcinolone Acetonide after Intravitreal Injection into Silicone Oil-Filled Eye

There is increasing use of the vitreous cavity as a reservoir for drug delivery. We study the intraocular migration and distribution of triamcinolone acetonide (TA) after injection into silicone oil tamponade agent during and after vitrectomy surgery ex vivo (pig eye) and in vitro (glass bottle). For ex vivo assessment, intraocular migration of TA was imaged using real-time FLASH MRI scans and ...

متن کامل

Attenuation of iodine 125 radiation with vitreous substitutes in the treatment of uveal melanoma.

OBJECTIVE To demonstrate attenuation of radiation from iodine 125 ((125)I) to intraocular structures using liquid vitreous substitutes. METHODS Four candidate vitreous substitutes were tested for attenuation using empirical measurement and theoretical calculation. In vitro and ex vivo cadaveric dosimetry measurements were obtained with lithium fluoride thermoluminescent dosimeters to demonstr...

متن کامل

Intraventricular Silicone Oil

Intracranial silicone oil is a rare complication of intraocular endotamponade with silicone oil. We describe a case of intraventricular silicone oil fortuitously observed 38 months after an intraocular tamponade for a complicated retinal detachment in an 82 year-old woman admitted in the Department of Neurology for a stroke. We confirm the migration of silicone oil along the optic nerve. We dis...

متن کامل

Removal of Silicone Oil From Intraocular Lens Using Novel Surgical Materials.

PURPOSE To design, fabricate, and evaluate novel materials to remove silicone oil (SiO) droplets from intraocular lenses (IOL) during vitreoretinal surgery. METHODS Three different designs were fabricated using soft lithography of polydimethylsiloxane (PDMS), three-dimensional (3D) inverse PDMS fabrication using water dissolvable particles, and atomic layer deposition (ALD) of alumina (Al2O3)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 1994