Central corneal thickness and applanation tonometry.

نویسندگان

  • Yuqiang Huang
  • Clement C Y Tham
  • Mingzhi Zhang
چکیده

after sub-Tenon anesthesia In their recent article, 1 Subbiah et al. noted that a rigid sub-Tenon cannula caused complications such as a retrobulbar hemorrhage, albeit rarely. The authors concluded that a ‘‘soft cannula’’ could be an ideal alternative for sub-Tenon injection in high-risk patients. We reported the same thing in our Sandwell technique, in which the soft plastic sheath of a Venflon was used to deliver the local anesthetic agent in the sub-Tenon space. This prevents injury to blood vessels in a highly vascular region during an essentially blind procedure. It is probably because our report was published in April 2007 that Subbiah et al. overlooked this very effective technique that addresses the point raised in the article. In our practice, we have found that the ultrashort version is not as effective as the Venflon sheath, as it often does not deliver the anesthetic agent to the actual retrobulbar region. Since our report, we have used this technique in all cases and have had no complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry.

OBJECTIVE To evaluate the effect of central corneal thickness (CCT), corneal curvature, and axial length on applanation tonometry in an in vivo study. METHODS In a masked, prospective clinical trial, we examined 125 eyes of 125 patients scheduled for cataract surgery. Corneal curvature was measured by means of keratometry and axial length by A-scan ultrasonography. By cannulating the anterior...

متن کامل

Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings.

BACKGROUND Several authors reported incorrect high intraocular pressure (IOP) values in eyes with a thick cornea using applanation tonometry. This hypothesis was checked by comparing applanation tonometry with direct intracameral manometry. METHODS 73 patients, scheduled for intraocular surgery, were enrolled. Immediately before surgery, the following were registered: (i) central corneal thic...

متن کامل

Pressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.

PURPOSE To compare pressure phosphene tonometry with Goldmann applanation tonometry for measuring intraocular pressure (IOP) before and after LASIK. METHODS Forty-three (18 men and 25 women) consecutive healthy patients underwent complete pre- and postoperative LASIK ophthalmologic assessments including manifest and cycloplegic refraction, keratometry, and central corneal thickness. Three rep...

متن کامل

Corneal thickness: It's time we all get rid of the correction factor from the glaucoma equation!

T measurement of central corneal thickness (CCT) by pachymetry plays an integral part of the contemporary glaucoma workup. It is one of the relatively simple and straightforward ancillary tests performed today in the clinic. Clinicians have embraced this measure since the emergence of understanding its impact on the accuracy of tonometry such as Goldmann applanation tonometry (GAT). GAT, which ...

متن کامل

Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature

PURPOSE The aim of the study was to assess the influence of central corneal thickness (CCT) and corneal curvature in tonometry measurements taken by Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry (DCT). METHODS This was a prospective study of 185 eyes from 97 subjects, attending outpatient ophthalmology appointments, who underwent intraocular pressure measurements b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 2008