Selecting an A1C Point-of-Care Instrument

نویسندگان

  • Heather P. Whitley
  • Ee Vonn Yong
  • Casey Rasinen
چکیده

A1C point-of-care (POC) instruments benefit patients with diabetes by facilitating clinician decision making that results in significant glycemic improvements. Three National Glycohemoglobin Standardization Program (NGSP)-certified POC products are available in the United States: the handheld A1CNow (formerly manufactured by Bayer Diabetes Care but now made by Chek Diagnostics) and two bench-top models called the Axis-Shield Afinion Analyzer and the Siemens DCA Vantage. This article compares the three available NGSP-certified POC products in terms of accuracy, precision, ease of use, cost, and additional features. Its goal is to aid health care facilities in conveniently identifying the A1C POC product that best meets their needs. It additionally reviews evidence that supports the continued use of A1C POC instruments in the clinical arena.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilizing a Diabetes Risk Test and A1c Point-of-Care Instrument to Identify Increased Risk for Diabetes In an Educational Dental Hygiene Setting.

PURPOSE The objective of this pilot study was to demonstrate the number of patients at increased risk for type 2 diabetes development using a validated survey; and to assess the rate of compliance for A1c screening in an educational dental hygiene setting. METHODS This was a descriptive study using a purposive sample of patients in an academic dental hygiene clinic, who were 18 years or older...

متن کامل

Impact of active versus usual algorithmic titration of basal insulin and point-of-care versus laboratory measurement of HbA1c on glycemic control in patients with type 2 diabetes: the Glycemic Optimization with Algorithms and Labs at Point of Care (GOAL A1C) trial.

OBJECTIVE The objective of this study was to assess the impact of active versus usual monitoring of algorithmic insulin titration and point-of-care (POC) versus laboratory HbA1c (A1C) measurement on glycemic control in primary care. RESEARCH DESIGN AND METHODS The Glycemic Optimization with Algorithms and Labs at Point of Care (GOAL A1C) study was a 24-week, randomized, parallel-group, four-a...

متن کامل

Glycated hemoglobin assessment in clinical practice: comparison of the A1cNow point-of-care device with central laboratory testing (GOAL A1C Study).

BACKGROUND The Glycemic Optimization with Algorithms and Labs At Po1nt of Care (GOAL A1C) Study assessed the effect of titration monitoring strategies and methods of A1C testing on glycemic control in patients with type 2 diabetes failing oral therapy and beginning basal insulin glargine. The availability of both point-of-care (POC) and central laboratory A1C values provided an opportunity to e...

متن کامل

Comparison of costs of hemoglobin A1c determination by point-of-care testing (POCT) and standard hemoglobin A1c analyzer

OBJECTIVE The use of the levels of hemoglobin A1c for the monitoring of glycemic control in patients with diabetes mellitus (DM) is an accepted method of clinical usefulness. A study was performed to assess the relative costs of hemoglobin A1c determination by diagnostic testing at or near the site of patient care (point-of-care testing, POCT) and using the standard hemoglobin A1c analyzer. MET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2015