A Study of Applying Pulsed Remote Field Eddy Current in Ferromagnetic Pipes Testing
نویسندگان
چکیده
Pulsed Remote Field Eddy Current Testing (PRFECT) attracts the attention in the testing of ferromagnetic pipes because of its continuous spectrum. This paper simulated the practical PRFECT of pipes by using ANSYS software and employed Least Squares Support Vector Regression (LSSVR) to extract the zero-crossing time to analyze the pipe thickness. As a result, a secondary peak is found in zero-crossing time when transmitter passed by a defect. The secondary peak will lead to wrong quantification and the localization of defects, especially when defects are found only at the transmitter location. Aiming to eliminate the secondary peaks, double sensing coils are set in the transition zone and Wiener deconvolution filter is applied. In the proposed method, position dependent response of the differential signals from the double sensing coils is calibrated by employing zero-mean normalization. The methods proposed in this paper are validated by analyzing the simulation signals and can improve the practicality of PRFECT of ferromagnetic pipes.
منابع مشابه
Pulsed Eddy Current Sensing for Critical Pipe Condition Assessment
Pulsed Eddy Current (PEC) sensing is used for Non-Destructive Evaluation (NDE) of the structural integrity of metallic structures in the aircraft, railway, oil and gas sectors. Urban water utilities also have extensive large ferromagnetic structures in the form of critical pressure pipe systems made of grey cast iron, ductile cast iron and mild steel. The associated material properties render N...
متن کاملSpatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy
The purpose of this paper is to introduce a new technique for row spacing measurement in a wire array using giant magnetoresistive (GMR) sensor. The self-rectifying property of the GMR-based probes leads to accurately detection of the magnetic field fluctuations caused by surface-breaking cracks in conductive materials, shape-induced magnetic anisotropy, etc. The ability to manufacture probes h...
متن کاملDevelopment of Pulsed Eddy Current Testing System for Wall Thinning through Insulation with Ferromagnetic Cladding
Corrosion is one of the important factors in equipment failures. Wall thinning can be used to evaluate corrosion conditions. However, most of equipments are coated with insulations in order to elevate the energy efficiency. Pulsed eddy current (PEC) testing technique can be used to measure wall thinning through insulation. But when the insulation outside is wrapped with galvanized steel, PEC si...
متن کاملDesign of Nondestructive System for Hardness of Carbonitrided Steel Parts Using Eddy Current Testing Method: Case study on the Tappet Parts
In this paper, a non-destructive eddy current test system was designed to evaluate the surface hardness of the carbonitrided steel parts. For this purpose, various samples of the tappet were used after the surface hardening and grinding operations as control samples and, if necessary, were subjected to destructive and non-destructive tests. Microstructural studies were performed with a microsco...
متن کاملCorrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing
Pulsed eddy current inspection techniques were derived from the conventional eddy current testing technology, based on the fundamental principle of an eddy current coil, but using periodic ultrasound pulses. The authors first introduce the principle of pulsed eddy current inspection and some experimental measurement results using pulsed eddy current equipment. This technology can be applied to ...
متن کامل