Is one cage enough in posterior lumbar interbody fusion: a comparison of unilateral single cage interbody fusion to bilateral cages.

نویسندگان

  • Guy R Fogel
  • John S Toohey
  • Arvo Neidre
  • John W Brantigan
چکیده

Posterior lumbar interbody fusion (PLIF), as recommended with bilateral lumbar interbody cages and pedicle screw fixation, has increased the successful fusion rate to nearly 100%. Presently, a unilateral approach to the disc space with a variant of PLIF, the trans-foraminal interbody fusion is often used. There are few clinical studies of unilateral interbody fusion. The clinical and fusion results of unilateral interbody fusion are important as the usage of trans-foraminal interbody fusion procedure increases. This retrospective study of 26 consecutive patients treated with a unilateral cage asks whether fusion healing and clinical outcome is comparable with that obtained with bilateral cages. In this study, there were no pseudarthroses, instrumentation failures, or significant subsidence at any of the single cage levels. Disc space height and foraminal height were restored by the surgery and maintained at last follow-up. Using Prolo scores, 23/26 patients had clinical success (88%), and 3 were unsuccessful. Fusion was successful at all single cage fusion levels and overall in 23/26 (88%) reviewing all levels of fusion. In conclusion, fusion and clinical success rates were not diminished by the use of a unilateral interbody cage rather than the recommended 2 cages. This retrospective comparative study is a Level III-2 Therapeutic Study investigating the results of unilateral PLIF with a single interbody cage compared with historical series with interbody cages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of cage height on the flexibility and load sharing of lumbar spine after lumbar interbody fusion with unilateral and bilateral instrumentation: a biomechanical study

BACKGROUND One- and two-level lumbar interbody fusion with unilateral instrumentation is as effective as that with bilateral instrumentation. The height of the interbody cage influences the operated segment stability and the fusion technique success. The purpose of this research was to determine the effect of the fusion cage height (i.e. long and short) on both the stability (based on flexibili...

متن کامل

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

Morphological analysis of interbody fusion following posterior lumbar interbody fusion with cages using computed tomography

Posterior lumbar interbody fusion (PLIF) using cages in conjunction with pedicle screw fixation is considered the gold standard for surgical treatment of degenerative lumbar spine disorders due to its biomechanical stability and high fusion rate. However, research regarding patterns of fusion in the interbody space during the early postoperative period is lacking.Sixty consecutive patients were...

متن کامل

Posterior Lumbar Interbody Fusion Using an Unilateral Cage: A Prospective Study of Clinical Outcome and Stability

OBJECTIVE The purpose of this study was to evaluate the clinical and radiological results of instrumented posterior lumbar interbody fusion (PLIF) using an unilateral cage. METHODS Seventeen patients with unilateral radiculopathy who underwent bilateral percutaneous screw fixation with a single fusion cage inserted on the symptomatic side for treatment of focal degenerative lumbar spine disea...

متن کامل

Modified posterior lumbar interbody fusion using a single cage with unilateral pedicle screws: a retrospective clinical study

BACKGROUND The traditional posterior lumbar interbody fusion (PLIF) technique usually involves implantation of two cages through a bilateral approach and bilateral laminectomy, which requires bilateral transpedicle screw fixation. The procedure itself has several negative impacts. Therefore, a modified PLIF procedure that includes insertion of a unilateral cage through the symptomatic side with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of spinal disorders & techniques

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2007