One hundred fecal specimens obtained from patients with acute gastroenteritis were tested for rotavirus with nine commercial immunoassays to evaluate the sensitivity, specificity, predictive value, and diagnostic accuracy of these assays. Kits evaluated included two monoclonal antibody-based enzyme immunoassays (EIAs) (Rotaclone and Pathfinder Rotavirus), three polyclonal antibody-based EIAs (Rotavirus Immunoassay, Rotazyme II, and Wellcozyme Rotavirus), and four latex agglutination assays (Rotastat, Virogen Rotatest, Meritec-Rotavirus, and The Wellcome Latex Test). Thirty-eight of the 100 specimens were found to contain rotavirus by a reference microplate EIA. The accuracy of the reference assay was determined by RNA electrophoresis and a blocking assay on discordant specimens. The two monoclonal antibody EIAs had superior sensitivities (100%) and identified two positive specimens which were negative by the reference method but positive by the blocking assay. Among the polyclonal EIAs, all had sensitivities of greater than 90%, but specificities were variable; Rotazyme II, with a specificity of 50%, showed considerable discrepancy from other polyclonal EIAs. The latex tests had sensitivities ranging from 70 to 90% and specificities of 80 to 100%. Latex agglutination tests were more rapid than EIAs and did not require expensive equipment. The final choice of assay system will depend on the cost, speed, and accuracy requirements of the clinical laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of five enzyme immunoassays, electron microscopy, and latex agglutination for detection of rotavirus in fecal specimens.

Five different enzyme immunoassays, electron microscopy, and latex agglutination (Slidex; bioMerieux) were compared for the rapid detection of human rotavirus in fecal specimens. The enzyme immunoassay using rotavirus polyclonal antiserum (Dakopatts) with simple in-house modifications was shown by the use of confirmatory tests to be the most sensitive and specific procedure.

متن کامل

Frequency of Rotavirus Infection in Children with Acute Gastroenteritis in Jahrom, South of Iran

Background: Rotavirus is a major cause of acute diarrhea in children worldwide. It is an important cause of death among young children in developing countries. The aim of this study was to evaluate the prevalence of rotavirus infection in children less than five years old hospitalized for gastroenteritis in Jahrom. Methods: One hundred and two stool samples were collected from children less tha...

متن کامل

Evaluation of the ImmunoCardSTAT! rotavirus assay for detection of group A rotavirus in fecal specimens.

Rapid detection of group A rotavirus was performed by using ImmunoCardStat! Rotavirus (ICS-RV) (which uses immunogold-based, horizontal-flow membrane technology), two commercial enzyme immunoassays (Premier Rotaclone and TestPack Rotavirus), and electron microscopy. A total of 249 stool specimens collected from children with gastroenteritis between February and April 1997 were tested. After res...

متن کامل

Comparison of electron microscopy, enzyme-linked immunosorbent assay and latex agglutination for the detection of bovine rotavirus in faeces.

The performance characteristics of 2 enzyme immunoassays (ELISAs) and 4 latex agglutination assays (LXs) were evaluated for the detection of bovine rotavirus in faecal specimens of young calves with diarrhoea. A total of 26 specimens from calves less than 5 months of age were examined with different commercial assays and compared with electron microscopy (EM) as the gold standard and with polya...

متن کامل

The prevalence of bacterial and viral agents in fecal specimens of children in Shiraz

in the present study 220 diarrheal samples of children aged between 3-12 months and 100 samples from healthy individuals of the same age group reffered to Shiraz university hospitals were investigated for bacterial and viral agents.Electron microscopy methods were used for the viral investigations,while conventional techniques of bacteriology were used for isolation of bacterial agents.the prev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 26 9  شماره 

صفحات  -

تاریخ انتشار 1988