Partial Breast and Breast Boost Radiotherapy Planned in the Prone Position: What Does MRI Add to X-ray CT Localization of Titanium Clips Placed in the Excision Cavity Wall?, International Journal of Radiation Oncology Biology Physics

نویسندگان

  • A M Kirby
  • J R Yarnold
  • P M Evans
  • V A Morgan
  • M A Schmidt
  • E D Scurr
  • N M DeSouza
  • Anna M. Kirby
  • John R. Yarnold
  • Philip M. Evans
  • Maria A. Schmidt
  • Erica D. Scurr
  • Nandita M. deSouza
چکیده

Purpose: To compare tumour bed (TB) volumes delineated using MRI plus CT/clips (MRCT) with those delineated using CT/clips-alone in post-lumpectomy breast cancer patients positioned prone, and to determine the value of MRCT for planning partial breast radiotherapy (PBI). Materials/ Methods: 30 women with breast cancer each had 6-12 titanium-clips secured in the excision cavity walls at lumpectomy. Patients underwent prone CT-imaging followed by prone MRI (T1-weighted (standard & fat-suppressed) and T2-weighted sequences). TB volumes were delineated separately on CT and fused-MRCT datasets. Clinical (CTV=TB+15mm) and planning target volumes (PTV=CTV+10mm) were generated. Conformity indices between CTand MRCT-defined target volumes were calculated (ratio of volume-of-agreement to total-delineatedvolume). Discordance was expressed as a geographical-miss index (GMI=fraction of totaldelineated-volume not defined by CT), and a normal-tissue index (NTI=fraction of totaldelineated-volume designated as normal tissue on MRCT). PBI dose-distributions were generated to cover CT-defined CTV (CTVCT) with ≥95% of the reference dose. The percentage of MRCT-defined CTV (CTVMRCT) receiving ≥95% of the reference dose was measured. Results: Mean conformity indices were 0.54 (TB), 0.84 (CTV) and 0.89 (PTV). For TB volumes, GMI was 0.37 and NTI was 0.09. Median percentage-volume coverage of CTVCT was 97.1% (range 95.3-100.0%), and of CTVMRCT was 96.5% (range 89.0-100.0%). Conclusions: Addition of MRto CT/clip-data generated TB-volumes that were discordant to those based on CT/clips-alone. However, clinically satisfactory coverage of CTVMRCT by CTVCTbased tangential PBI fields provides support for CT/clip-based TB delineation remaining the method of choice for PBI/ breast boost radiotherapy planned using tangential fields. MRCT tumor bed delineation for partial breast RT Kirby page 3

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Evaluation of changes in excision cavity volume during whole breast irradiation using secondary CT image

Background: The aim of this study was to evaluate the reduction in excision cavity volume (ECV) during the whole breast radiotherapy (WBRT). The delineating of reduced cavity volume on secondary CT (computed tomography) might decrease the field size of boost plan. Materials and Methods: Twenty patients were treated having breast conservative surgery. At first, primary CT simulation (CT-1) was d...

متن کامل

Tumour bed delineation for partial breast/breast boost radiotherapy: what is the optimal number of implanted markers?

PURPOSE International consensus has not been reached regarding the optimal number of implanted tumour bed (TB) markers for partial breast/breast boost radiotherapy target volume delineation. Four common methods are: insertion of 6 clips (4 radial, 1 deep and 1 superficial), 5 clips (4 radial and 1 deep), 1 clip at the chest wall, and no clips. We compared TB volumes delineated using 6, 5, 1 and...

متن کامل

Ultrasound-guided boost irradiation of tumor cavity after lumpectomy in breast cancer

Background:  After breast conserving surgery, most recurrences occur around the primary tumor site. This justifies the use of boost radiotherapy to the primary site of tumor. Surgical scar is not always a good surrogate for the location of the lumpectomy cavity. The aim of this study was to evaluate ultrasonic guidance for detection of the lumpectomy cavity after breast conserving surgery ...

متن کامل

Effect of uniform magnetic field on dose distribution in the breast radiotherapy

Background: To reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. Materials and Methods: Monte Carlo simulations were performed with GEANT4, irradiating humanoid phantoms in a magnetic field. To reconstruct phantoms, computed tomography (CT) data slices of four patients were used for the Monte Car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010