A New Reading out Procedure to Improve the Linearity of Dose Response curve of Lif: mg, TI

نویسندگان

  • A. I. Abd El-Hafez
  • M. S. El-Nagdy
چکیده

The linearity of thermoluminescence (TL) dose response curve, in low dose levels, is affected by background signals appearing at the tail of the glow curves. The effects of these signals also restrict the use of the high temperature glow peaks in many applications. In this study, a new reading out procedure was presented to reduce the background signals and increase the resolution of the high temperature glow peaks in LiF:Mg,Ti (TLD-600 and TLD-700) dosimeters in both gamma and neutron irradiation processes. The new reading out procedure was performed in two steps with different temperature zone range. In the first step, the temperature zone range was set to 100:210 C with heating rate R= 1 C/sec. This step is followed by a second reading (second step) with a temperature zone range of 100:400 C with the same R. A comparison between this new procedure and the usual one (in which the reading out is only one step with a temperature zone of 100:400 C) was performed. The new behavior of the glow peaks due to applying these procedures was also studied. The results show that the new procedure causes in decreasing the maximum value (Im) of the glow peaks. However, their position (Tm) did not affect. The percentage values by which the Im of the glow peaks decreased are the same in both irradiation cases for peaks 2, 3 and 5. The results also show that this procedure decreases the background signals appearing in the tail of the glow curve, especially in the case of neutron irradiation. Hence, it increases the resolution of the high temperature glow peaks, especially peak 7. A significant improvement in the linearity of the TL dose response was observed for due to applying this procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Validation Study on Radiation properties of a Novel LiF: Mg, Ti Known as IAP-100

Introduction: LiF dosimeter has the most application in medicine. This study aimed to evaluate some dosimetric properties of a novel LiF: Mg, Ti. Materials and Methods: An ELEKTA Precise linear accelerator was used to calibrate dosimeters at 6 MV. In this survey, responses of dosimeters were evaluated up to 1000 cGy. Background effect was investigated in two different dosimeter states includin...

متن کامل

تولید دزیمتر LiF: Mg, Ti و مقایسه پاسخ آن با دزیمتر (LiF: Mg, Ti (TLD-100 ساخت شرکت هارشا در برابر پرتوهای گاما

Thermoluminescence dosimeters are small tablets used with 3. 2*3. 2*0. 9mm^3 for measurement of received dose from radioactive various beams. The most common dosimeter is TLD-100 which is lithium-fluoride family and this dosimeter contain magnesium impurities. In this study, first lithium-flouride powder was mixed with titanium and controlled atmosphere samples were heated. After measuring ...

متن کامل

Evaluation of the Entrance Skin Dose in Animals Undergoing Diagnostic Radiology Using LiF, Mg, Ti Thermoluminescence Dosimetry (TLD-100)

Introduction According to the International Commission on Radiological Protection publication numbers 60 and 21, the environmental control standards should ensure human and other species protection to a desirable degree. Since application of radiographic procedures in Veterinary Medicine has increased significantly, in this study, we aimed to evaluate the entrance skin dose to the animals (e.g....

متن کامل

SU-E-T-102: Evaluation of the Characteristics of TLD LiF:Mg.Ti-100 Powder: A Measure of Consistency between Multiple Batches of Powder.

PURPOSE Analyze the characteristics of TLD LiF-100 powder between multiple LiF crystal batches. METHODS The RPC used TLD LiF-100 encapsulated powder to verify the output for photon and electron beams for 4 to 23 MV X-ray beams and 6 to 23 MeV electron beams, respectively, from the past 15 years. During that time period, the RPC commissioned more than 15 batches of TLD powder. Commissioning of...

متن کامل

Investigation of LiF, Mg and Ti (TLD-100) Reproducibility

LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013