Excellent durability of Starr-Edwards ball valves implanted in the aortic and mitral positions for 27 years: report of a rare surgical case.

نویسندگان

  • Masato Tochii
  • Yasushi Takagi
  • Kan Kaneko
  • Michiko Ishida
  • Kiyotoshi Akita
  • Yoshiro Higuchi
  • Motomi Ando
چکیده

A 59-year-old male who had undergone aortic and mitral valve replacement with Starr-Edwards ball valves 27 years ago was admitted to our hospital for hemolytic anemia and heart failure. Echocardiography revealed prosthetic valve failure with a high-pressure gradient and small effective orifice area. The Starr-Edwards ball valves were successfully replaced with bileaflet mechanical valves. The explanted valves revealed no structural abnormalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis

We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic--no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial...

متن کامل

Extended Durability of a Cloth-Covered Star-Edwards Caged Ball Prosthesis in Aortic Position

The Starr-Edwards caged ball valve is one of the oldest cardiac valve prosthesis and was widely used all around the world in the past decades. Despite the long-term results that have been reported there are only a few cases reported that exceed 30 years of durability. Here in, we report a 53-year-old patient with a well-functioning 35-year-old aortic Starr-Edwards caged ball prosthesis.

متن کامل

Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...

متن کامل

Ten year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.

The long term performance characteristics of the 2400 and 1260 series of Starr-Edwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2013