Dynamic organ modeling for minimally-invasive cardiac surgery
نویسندگان
چکیده
While most currently available minimally invasive robotically assisted cardiac surgical systems do not employ 3D image guidance, such support can be generated using pre operative images such as CT. Previously we demonstrated a virtual model of the thorax with simulated surgical instruments, and a pulsating virtual model of the coronary arteries. In this paper we report the overlay of optical endoscopic images of a beating heart phantom with CT-based dynamic volumetric images of the phantom. Spatial matching is obtained through optical tracking of the endoscope and of the phantom, while time synchronization of the display of the model utilizes ECG gating. The spatial accuracy between the optical and virtual images varies from about 0.8 mm to –2.6 mm, while the time discrepancy depends on the frame-rate at which the virtual model is refreshed, and is typically 50-100 ms. Although the CT-based dynamic images are sufficient for animation of the model, artefacts associated with the image registration prevent seamless animation. Instead, to reconstruct the various phases of heart pulsation, we used a high-quality semi-static image of the diastolic phase of the phantom, and warped it to match the CT-based images corresponding to other phases of the heart pulsation.
منابع مشابه
Cardiac Endoscopy Enhanced by Dynamic Organ Modeling for Minimally-Invasive Surgery Guidance
The development of a 3D image guidance environment will significantly enhance the performance of minimally invasive robotically assisted cardiac surgery. We have previously reported early progress on generation of such virtual environment, and linking it with traditional modalities like endoscopy. This paper discusses one aspect of the surgical navigation system: near-real time animation of the...
متن کاملThe Body Image Dissatisfaction and Psychological Symptoms among Invasive and Minimally Invasive Aesthetic Surgery Patients
BACKGROUND Elective aesthetic surgeries are increasing in the Iranian population with reasons linked to body image dissatisfaction and psychological symptoms. This study compared the body image dissatisfaction and psychological symptoms among invasive and minimally invasive aesthetic surgery patients and a control group. METHODS Data from 90 participants (invasive aesthetic surgery=30 ...
متن کاملNeurological Study of Radial Nerve Conduction During Endoscopic Radial Artery Harvesting:An Intra‐Operative Evaluation
Endoscopic radial artery harvesting (ERAH) is a feasible and attractive minimally invasive approach for conduit procurement, however there have been concerns about a potential neurological damage occurring at the harvest limb site secondary to injury of the radial nerve during endoscopic harvesting. We present a case of ERAH in which we evaluated intraoperatively the characteristics of radial n...
متن کاملMinimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip
Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to ...
متن کامل4D Motion Modeling of the Coronary Arteries from CT Images for Robotic Assisted Minimally Invasive Surgery
In this paper, we present a novel approach for coronary artery motion modeling from cardiac Computed Tomography(CT) images. The aim of this work is to develop a 4D motion model of the coronaries for image guidance in robotic-assisted totally endoscopic coronary artery bypass (TECAB) surgery. To utilize the pre-operative cardiac images to guide the minimally invasive surgery, it is essential to ...
متن کامل