Optimization of Computational Control-Parameter Values for Dynamic Optical Tomographic Image Reconstruction

نویسندگان

  • Harry L. Graber
  • Stephanie Y. Lum
  • Yong Xu
  • Randall L. Barbour
چکیده

Figure 7. Numerical demonstration of utility of SI for gauging similarity between time series. Top: noisy phase-modulated sine waves with a common carrier frequency and common initial phase. Starting at the 250-second mark, a 500-point segment of one was substituted with a 90° phase-shifted copy of the other. Bottom: numerically computed SI at the carrier frequency. Detector S ou rc e Reciprocal Channel Correlations, -LPF

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

Layered 3D: Tomographic Image Synthesis forttenuation-based Light Field and High Dynamic Range Displays

We develop tomographic techniques for image synthesis on displays composed of compact volumes of light-attenuating material. Such volumetric attenuators recreate a 4D light field or highcontrast 2D image when illuminated by a uniform backlight. Since arbitrary oblique views may be inconsistent with any single attenuator, iterative tomographic reconstruction minimizes the difference between the ...

متن کامل

Parameter optimization in 3D reconstruction on a large scale grid

Reaching as high structural resolution as possible in 3D electron microscopy of biological specimens is crucial to understanding their function and interactions. Technical and biological limitations make electron microscopy projections of such specimens quite noisy. Under those circumstances, the broadly used Weighted Back-Projection algorithm presents some limitations for 3D reconstruction. It...

متن کامل

A LSQR-type method provides a computationally efficient automated optimal choice of regularization parameter in diffuse optical tomography.

PURPOSE Developing a computationally efficient automated method for the optimal choice of regularization parameter in diffuse optical tomography. METHODS The least-squares QR (LSQR)-type method that uses Lanczos bidiagonalization is known to be computationally efficient in performing the reconstruction procedure in diffuse optical tomography. The same is effectively deployed via an optimizati...

متن کامل

Optical tomography as a PDE-constrained optimization problem

We report on the implementation of an augmented Lagrangian approach for solving the inverse problems in diffuse optical tomography (DOT). The forward model of light propagation is the radiative transport equation (RTE). The inverse problem is formulated as a minimization problem with the RTE being considered as an equality constraint on the set of ‘optical properties—radiance’ pairs. This appro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009