Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

نویسندگان

  • Danny J.J. Wang
  • Jeffry R. Alger
  • Joe X. Qiao
  • Matthias Gunther
  • Whitney B. Pope
  • Jeffrey L. Saver
  • Noriko Salamon
  • David S. Liebeskind
چکیده

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 men) with acute middle cerebral artery (MCA) stroke who also underwent dynamic susceptibility contrast (DSC) enhanced perfusion imaging. Arterial transit times (ATT) were estimated through the calculation of weighted delays across the 4 PLDs, which were included in the calculation of cerebral blood flow (CBF) and arterial cerebral blood volume (CBV). Mean perfusion parameters derived using pCASL and DSC were measured within MCA territories and infarct regions identified on diffusion weighted MRI. The results showed highly significant correlations between pCASL and DSC CBF measurements (r > = 0.70, p < = 0.0001) and moderately significant correlations between pCASL and DSC CBV measurements (r > = 0.45, p < = 0.027) in both MCA territories and infarct regions. ASL ATT showed correlations with DSC time to the maximum of tissue residual function (Tmax)(r = 0.66, p = 0.0005) and mean transit time (MTT)(r = 0.59, p = 0.0023) in leptomeningeal MCA territories. The present study demonstrated the feasibility for noninvasive multi-parametric perfusion imaging using ASL for acute stroke imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The value of arterial spin-labeled perfusion imaging in acute ischemic stroke: comparison with dynamic susceptibility contrast-enhanced MRI.

BACKGROUND AND PURPOSE The purpose of this study was to evaluate the potential clinical value of arterial spin-labeled (ASL) perfusion MRI in acute ischemic stroke (AIS) through comparison with dynamic susceptibility contrast (DSC) enhanced perfusion MRI. METHODS Pseudocontinuous ASL with 3-dimensional background-suppressed gradient and spin echo readout was applied with DSC perfusion MRI on ...

متن کامل

Quantitative analysis of hypoperfusion in acute stroke: arterial spin labeling versus dynamic susceptibility contrast.

BACKGROUND AND PURPOSE This study compares the concordance between arterial spin labeling (ASL) and dynamic susceptibility contrast (DSC) for the identification of regional hypoperfusion and diffusion-perfusion mismatch tissue classification using a quantitative method. METHODS The inclusion criteria for this retrospective study were as follows: patients with acute ischemic syndrome with symp...

متن کامل

Comparison of Arterial Spin Labeling and Dynamic Susceptibility Contrast Perfusion MRI in Patients with Acute Stroke

BACKGROUND The aim of this study was to evaluate whether arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC) perfusion MRI. METHODS Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans wi...

متن کامل

Patterns of postictal cerebral perfusion in idiopathic generalized epilepsy: a multi-delay multi-parametric arterial spin labelling perfusion MRI study

The cerebral haemodynamic status of idiopathic generalized epilepsy (IGE) is a very complicated process. Little attention has been paid to cerebral blood flow (CBF) alterations in IGE detected by arterial spin labelling (ASL) perfusion magnetic resonance imaging (MRI). However, the selection of an optimal delay time is difficult for single-delay ASL. Multi-delay multi-parametric ASL perfusion M...

متن کامل

Combined low-dose contrast-enhanced MR angiography and perfusion for acute ischemic stroke at 3T: A more efficient stroke protocol.

BACKGROUND AND PURPOSE There is need to improve image acquisition speed for MR imaging in evaluation of patients with acute ischemic stroke. The purpose of this study was to evaluate the feasibility of a 3T MR stroke protocol that combines low-dose contrast-enhanced MRA and dynamic susceptibility contrast perfusion, without additional contrast. METHODS Thirty patients with acute stroke who un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013