Cutting precision in a novel aortic valve resection tool. Research in progress.

نویسندگان

  • Daniel Wendt
  • Sebastian Stühle
  • Hermann Wendt
  • Matthias Thielmann
  • Brigitte Kipfmüller
  • Florian Hauck
  • Bernd Vogel
  • Heinz Jakob
چکیده

BACKGROUND We recently demonstrated the first in-vitro cutting results of a minimal-invasive aortic valve resection tool. The current study was designed to assess the cutting accuracy of this new device improved by the implementation of a linear motor-based propulsion unit. METHODS Native aortic valves of isolated swine hearts (valve diameter 17.8+/-0.9 mm, mean+/-S.D.) were artificially stenosed and calcified (n=7). Subsequently, valves were resected by the use of a new aortic valve resection tool. The cutting process was performed by fitting the instrument with foldable Nitinol cutting blades (diameter 15 mm) and two software-operated linear motors combined with separated manual rotation. Aortic valve area was measured pre- and postprocedure by software-guided binary area calculation. Aortic valve residue has been determined and the grade of accuracy has been assessed via calculating the average midpoint of the neoannulus. Furthermore, radial deviation of concentricity was calculated and cutting time was measured. RESULTS Aortic valve resection was successful in all cases and nearly all leaflets (2.5+/-0.4) with a weight of 0.22+/-0.12 g were cut. Aortic valve area increased significantly (0.3+/-0.1 cm(2) vs. 1.1+/-0.2 cm(2), P<0.001) with a mean cutting time of 49.7+/-15.0 s. Mean lateral leaflet rim within the annulus was 3.2+/-3.2 mm. Cutting precision revealed a median deviation of the cutting ring from the desired position of 1.3+/-0.6 mm (y-axis) and 1.4+/-0.5 mm (x-axis). Median center deviation of the cutting ring was 2.6+/-0.8 mm. CONCLUSIONS The present study clearly confirmed ability of an accelerated cutting of stenotic aortic valve by the aortic valve resection tool. Nearly all leaflets were cut and a small rim was left within the annulus, hence providing an ideal 'landing zone' for the new prosthesis. Nevertheless, the aortic valve resection tool should be enhanced by adding a centering mechanism, thus achieving a more precise cutting process in order to avoid secondary damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evolution of Precision Medicine and Surgical Strategies for Bicuspid Aortic Valve-Associated Aortopathy

Bicuspid aortic valve (BAV) is a common congenital cardiac malformation affecting 1-2% of people. BAV results from fusion of two adjacent aortic valve cusps, and is associated with dilatation of the aorta, known as bicuspid valve associated aortopathy. Bicuspid valve aortopathy is progressive and associated with catastrophic clinical events, such as aortic dissection and rupture. Therefore, fre...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 2009