Resolving Those Pesky X-ray Detector's Dead Time and Pileup Errors
نویسنده
چکیده
Resolving those Pesky X-ray Detector’s Dead Time and Pileup Errors
منابع مشابه
Dead time and pileup in pulsed parametric X-ray spectroscopy
Spectroscopy of parametric X-rays (PXR) from pulsed electron sources is usually done with very low electron beam currents in order to avoid dead time losses and pileup problems. This paper presents a method that allows correction of dead time losses and pileup in pulsed X-ray spectroscopy. Such correction is required in order to study the variation of PXR production and linewidth with increased...
متن کاملTheoritical Considerations in the Design of Dead Time and Pileup Corrections in a Simple Two-Channel Digital Nuclear Radiation Measurement System
The sources of errors associated with the measurement of nuclear radiations includethe noise associated with the radiation pulse, the dead time required for the processing of the incident radiation pulse and the pileup of pulses. In analogue processing, these errors are often downplayed leading to appreciable errors in the observed results. Some digital processors have been designed and built a...
متن کاملEvaluation of models of spectral distortions in photon-counting detectors for computed tomography.
A semi-analytical model describing spectral distortions in photon-counting detectors (PCDs) for clinical computed tomography was evaluated using simulated data. The distortions were due to count rate-independent spectral response effects and count rate-dependent pulse-pileup effects and the model predicted both the mean count rates and the spectral shape. The model parameters were calculated us...
متن کاملEvent Pileup in Charge-coupled Devices
The problem of event pileup in single-photonÈcounting CCD cameras (e.g., in the X-ray regime) is discussed, and a solution to the problem is proposed. The resulting pileup equation includes the e†ects of grade migration and presents itself as a nonlinear modiÐcation to the standard integral equation used by forward-folding spectral-Ðtting programs. The e†ectiveness of the model is demonstrated ...
متن کاملChandra imaging spectroscopy of 1 E 1740 . 7 – 2942
We have observed the black hole candidate 1E 1740.7 –2942, the brightest persistent hard X-ray source within a few degrees of the Galactic centre, for 10 ksec with Chandra (ACIS-I) on August 2000. Attempting to compensate for pileup effects we found the spectra were well-fit by an absorbed power law, with photon indices Γ = 1.54 −0.14 (annulus), consistent with a black hole low/hard state. We h...
متن کامل